ROW serial precision balance users manual
SECTION 10 CALIBRATION
Press UNIT key and M+ key together when normal weighing mode, display shows
F0 H-L, press TARE key until display shows PrOG, press ZERO key, display
shows PIN, You can press G/NUNITZERO key to enter setting mode, press
TARE key to select "p2 CAL", press ZERO key to sure. press TARE key to
select .While it is showing "CAL " press the ZERO key to enter. The display will
show "linear".
1. Normal calibrate
Press TARE key to select "nonlin".then press the ZERO key to enter,the display
shows: "unload Remove any weight from the platform. After stable indicator on,
press the ZERO key.
Then the display will show the last calibration weight used. If this is correct ,you can
continue by pressing the ZERO key. If it is not correct use the M+, G/N, TARE
keys to change the calibration weight value. When it is correct press the ZERO key.
Then display will show LoAd. Place the calibration weight on the scale. After
stable, press the ZERO key. Then the calibration has completed.
2. Linear calibrate
Press the ZERO key to enter,the display shows: "ld 0 , Remove any weight from the
platform. After stable indicator on, press the ZERO key.
Then display will show Ld 1. Place the 1/3 of capacity calibration weight on the
scale. After stable, press the ZERO key.
Then display will show Ld 2. Place the 2/3 of capacity calibration weight on the
scale. After stable, press the ZERO key.
Then display will show Ld 3 . Place the full capacity calibration weight on the scale.
After stable, press the ZERO key. Then the calibration has completed.
If the calibration is acceptable the display will return to normal. If an error message
is shown try calibration again as a disturbance may have prevented a successful
calibration.
If the problem persist then contact your dealer.
After calibration the scale should be checked to verify the calibration and linearity is
correct. If necessary repeat calibration, especially be certain the scale is stable
before accepting any weight.
-16-

Other manuals for T Scale ROW Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the T Scale ROW Series and is the answer not in the manual?

T Scale ROW Series Specifications

General IconGeneral
BrandT Scale
ModelROW Series
CategoryScales
LanguageEnglish

Related product manuals