RWP Weighing Indicator Technical Manual(v1.16)
Bring the load on to the platform.
When the load few seconds get stable, the reading will be locked for few
seconds and will be follow beep.
It can add or remove loads also update the weighing locked values.
5.12. Peak Hold
RWS can operate peak hold function, maximum reading will be hold and
will update automatically when adding the goods.
For this function, select parameter P4 CHk to ModE 4
In the normal weighing mode press and key together to turn on
Peak hold operations, display will be indicate HOLD.
If want to turn off peak function, press and key together again
5.13. Backlight Setting
In the weighing mode. Press key and key to select
parameter F3 OFF >BL. press key to select (BK AU/BK
OFF/BK ON), After select the back light option press key to confirm
and press key to escape from the settings.
5.14. Auto Power Off Setting
In the weighing mode. Press key and key to select
parameter F3 OFF >SET OF , press key to change auto power
off time: 0/3/5/15/30. (of 0: always on, of xx: auto power off after
standby xx minutes), press key to sure, press key to escape.
5.15subtraction scale
This is used for hopper scale, you need set auto zero range to 0 (see
detail in section 6 and set scale mode to mode 3
Turn on power, scale will show “err4”, then show current total weight on
platform, press key , display show 0.00, then remove goods in
hopper, display will show it’s weight in “-“ mode, press key, scale
will print out weighing ticket。