RWP Weighing Indicator Technical Manual(v1.16)
- 29 -
10
. ERROR CODES
Error Message
Description
Solution
-----
Maximum load exceeded
Unload or reduce weight
Err 1
Incorrect date
Enter the date by using format
“yy;mm:dd”
Err 2
Incorrect time
Enter the time by using format
“hh:mm:ss”
Err 4
Zero setting error
Zero setting range exceeded
due to switching on.(4%max)
Make sure platform empty.
Err 5
Key board error
Check the keys and
connecter.
Err 6
A/D value out of range
Make sure platform empty and
check the pan is installed
proper. Check the load cell
connectors.
Err 7
Percentage error
Value should be (0.01%
weight must > 0.5d)
Err 9
Unstable Reading
Check any air variation,
vibration, RF noise and
touching some where.
Check the load cell and
connecters.
Err 10
Communication error
No data (RS-232, continuous
communication)
Err 15
Enter gravity error
Gravity rang(0.9~1.0)
Err 17
Tare out of range
Remove the load and restart
scale again.
Err19
Initialize zero error
Calibration the scale.
--ol--
Over range
Remove the load.
Re calibrate
Fai l h
/
fai l l
Calibration Error
Re calibrate
Err p
Printer error
Check the printer and settings
Ba lo
/
lo ba
Battery low
Re charge battery, check the
voltages.