Connector J100 is fitted as standard as it is used for factory loading of the
initial bootloader code. JTAG connector J106 is only fitted to prototype
boards used for debugging of DSP code. It cannot be fitted to production
boards as it is placed on the underside of the ASIF PCB; it is not possible to
fit boards equipped with J106 on to the reciter heatsink.