HYDRAULIC UNITS
SOLENOID VALVE
IV-64TB53FR
Replace
Replace
Overhaul and repair or replace.
Overhaul and repair or replace.
Overhaul and repair or replace.
Overhaul and repair or replace.
INSPECTION AND ADJUSTMENT
Checking the Parts
Parts
Replace
Replace
TROUBLESHOOTING
Symptom
Solenoid valve does not
operate.
Wiring short-circuit or wire break
Solenoid coil short-circuit or wire break
Catching of foreign matter by the spool
Damage on the outer circumference of the spool
Catching of foreign matter by the plunger
Damage on the outer circumference of the plunger
Solenoid coil When the solenoid is burned, short-circuited, or has a wire
break
Wiring short-circuit or wire break
Judgment Criteria Treatment
Scratches, rust, or corrosion at the sliding parts with the spool
Scratches, rust, or corrosion of the seal part in contact with the
O-ring
Other damage considered to impair the normal functions
Damage on the outer circumference which catches a fingernail
No smooth movement
Rust, corrosion, deformation, breakage, or other notable dam-
age

Body
Spool, plunger
Spring
O-Ring
Replace
Replace
Replace
Replace
Adjust or replace
Replace
Replace
Probable Causes Remedy
Replace
Replace
Damaged O-ring
Damaged O-ring at the emergency manual but-
ton of the solenoid valve
Oil leakage from solenoid
valve, cover, or relief
valve to the outside.
Pressure does not rise. Catching of foreign matter by the relief valve Clean or replace.