TROUBLESHOOTING
ARM
V-36TB53FR
5. Inspect the arm cylinder.
a. Fully retract the bucket cylinder, fully retract
the arm cylinder and lower the bucket to the
ground.
b. Disconnect the two hoses connected to the
cylinder. Insert plugs (1) in the disconnected
hoses and the cylinder piping.
c. Raise the boom and raise the hoe attachment so
it floats above the ground. If the arm dorps, the
cylinder is faulty. If the arm does not drop,
there is leakage inside the control valve.