105
MAINTENANCE
Daily Inspection (Every 10 Hours)
Perform the following inspections once every day before starting the engine the first time.
WARNING
¡¡
¡¡
¡Before operating, perform the Daily inspections and make repairs immediately should
any irregularities be found.
¡¡
¡¡
¡Be sure to secure the engine hood or cover when opening it. Do not open the engine
hood or cover on slopes or in strong wind.
Inspecting and Replenishing the
Coolant
WARNING
Do not remove the radiator cap or drain
plugs when the coolant is hot. Stop the
engine, let the engine and radiator cool
and loosen the radiator cap or drain plugs
slowly.
Inspection
1. Open the engine hood.
2. Inspect the quantity of coolant in the
reserve tank (1).
The level should be between the upper
limit (H) and lower limit (L).
If it is below the lower limit (L), replenish.
3
J1G014
1
H
2
L
Replenishing
1. Remove the reserve tank’s cap (2).
2. Add coolant up to the upper limit (H) of
the reserve tank (1).
If the reserve tank is empty, inspect for
fluid leakage, then inspect the radiator
coolant level. If it is low, add water to the
radiator first, then to the reserve tank.
3. Install the cap (2).

Table of Contents

Other manuals for Takeuchi TB53FR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Takeuchi TB53FR and is the answer not in the manual?

Takeuchi TB53FR Specifications

General IconGeneral
BrandTakeuchi
ModelTB53FR
CategoryCompact Excavator
LanguageEnglish

Related product manuals