SAFETY
Starting Precautions
Starting with jumper cables
E3A200
Use
jumper cables only
in
the recommended
manner.
Improper use of jumper cables can
result
in
battery explosion or unexpected
machine motion.
Refer to the section titled "If the Battery Goes
Dead" for proper instructions.
After starting the engine
After starting the engine, perform the
following operations and checks
in
a safe
place with no persons or obstacles
in
the
area. If
any
malfunctions
are
found, follow
the shutdown procedure and report the
malfunction.
Warm
up the engine and hydraulics.
Observe
all
gauges
and
warning
instruments for proper operation.
Listen for unusual noises.
Test
engine speed control.
Operate each control to ensure proper
operation.
18
In
cold weather
E3A280
Be
careful of slippery conditions
on
freezing ground, steps and hand holds.
In
severe cold weather,
do
not touch any
metal parts of the machine with exposed
flesh, because flesh can freeze to the
metal
and
cause
injury.
Do
not
use
ether or starting fluids
on
this
engine. These starting aids
can
cause
explosion and serious injury or death.
Warm
up the engine and hydraulic fluid
before operating.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Takeuchi TL250 and is the answer not in the manual?

Takeuchi TL250 Specifications

General IconGeneral
Engine MakeYanmar
Engine Power74 hp
Lift Height3, 275 mm
Net Power73.5 kW
Travel Speed - High11.8 km/h
Hydraulic Pump Flow92.5 L/min
Auxiliary Hydraulic Flow92.5 L/min