5-34
MAINTENANCE
EVERY 50 HOURS
Replenishing
When adding distilled water, do so before
starting operations in order to prevent
freezing.
1. Remove the bolts (a) and open the
radiator (b).
2. Remove the R-pin (e) from the stay (c).
3. Insert the stay (c) into the hole (d) to
secure the radiator (b).
4. Loosen the sealing plugs (1) and add
distilled water up to the highest level line
(H).
5. Securely tighten the sealing plugs (1).
INSPECTING THE BUCKET STOPPERS
(BOLTS/NUTS)
Before performing maintenance or repairs
under the machine, lower all movable
working equipment to the ground or in
the lowermost position.
1. Park the machine on a flat and rigid
ground, and remove the bucket.
2. Retract the bucket cylinders and lift
cylinders to the minimum length.
3. Inspect the adjusting bolts (1) and lock
nuts (2) for bending, denting, deformation
and looseness.
4. If there are any irregularities with the
adjusting bolts (1) and/or lock nuts (2),
replace them with new ones. After
replacement, they require adjustment.
Contact a Takeuchi service agent for
advice
Refer to “Adjusting or replacing the bucket
stoppers (bolts/nuts)” on page 5-46.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Takeuchi TL8 and is the answer not in the manual?

Takeuchi TL8 Specifications

General IconGeneral
Tipping Load6, 021 lbs
Engine MakeKubota
Engine ModelV3307-CR-TE4
Rated Operating Capacity2, 107 lbs
Auxiliary Hydraulics - High FlowNot available
Gross PowerNot available

Related product manuals