EasyManua.ls Logo

T&S ChekPoint EC-3100 - User Manual

T&S ChekPoint EC-3100
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation and
Maintenance
Instructions
EC-3100 Series
ChekPoint
ELECTRONIC FAUCET
DECK-MOUNT & WALL-MOUNT
GOOSENECK, SPOUT & 4”
CENTERSET SENSOR
OPERATED
Limited One Year Warranty
T&S warrants to the original purchaser (other
than for purposes of resale) that such product is
free from defects in material and workmanship for
a period of one (1) year from the date of purchase.
During this one-year warranty period, if the product
is found to be defective, T&S shall, at its options,
repair and/or replace it. To obtain warranty service,
products must be returned to...
T&S Brass and Bronze Works, Inc.
Attn: Warranty Repair Department
2 Saddleback Cove
Travelers Rest, SC 29690
Shipping, freight, insurance, and other
transportation charges of the product to T&S and
the return of repaired or replaced product to the
purchaser are the responsibility of the purchaser.
Repair and/or replacement shall be made within a
reasonable time after receipt by T&S of the returned
product. This warranty does not cover Items which
have received secondary nishing or have been
altered or modi ed after purchase, or for defects
caused by physical abuse to or misuse of the
product, or shipment of the products.
Any express warranty not provided herein, and
any remedy for Breach of Contract which might
arise, is hereby excluded and disclaimed. Any
implied warranties of merchantability or tness
for a particular purpose are limited to one year in
duration. Under no circumstances shall T&S be
liable for loss of use or any special consequential
costs, expenses or damages.
Some states do not allow limitations on how
long and implied warranty lasts or the exclusion or
limitation of incidental or consequential damages,
so the above limitations or exclusions may not apply
to you. Speci c rights under this warranty and other
rights vary from state to state.
P/N: 098-016361-45 Rev.6
Date: 04-22-14
Drawn: TEH
Checked: GEF 05-07-14
Approved: JHB 05-07-14
EC-3100
EC-3101
EC-3102
EC-3103
EC-3106

Questions and Answers

  • M
    Marilyn MendozaAug 4, 2025
    Why does my T&S ChekPoint EC-3100 keep turning on by itself?
    • J
      jennifer03Aug 4, 2025
      If your T&S Plumbing Product is activating without anyone near it, the detection range might be too long; try decreasing the detection zone. Also, examine the surrounding area for anything that could be affecting the range, such as bright lights, reflective surfaces, or direct sunlight.
  • R
    Rebecca NicholsonAug 11, 2025
    What to do if T&S Plumbing Product has very low flow?
    • C
      Calvin NicholsAug 11, 2025
      If you're experiencing very low flow or just a slow dribble from your T&S Plumbing Product, there are a few things you can check: * Make sure the supply stops are fully open. * There might be debris in the solenoid filter; remove it, clean it, and then reinstall it. * The aerator or spray head could also be clogged with debris; remove, clean, and reinstall those as well.
  • C
    Charles BlairAug 18, 2025
    How to fix no water flow with red LED on T&S ChekPoint EC-3100 Plumbing Product?
    • P
      Paula HendersonAug 18, 2025
      If your T&S Plumbing Product isn't dispensing water and the red LED is lit, try these steps: First, replace the batteries and ensure the transformer is properly plugged in. If that doesn't work, the sensor range might be too long or picking up the sink; try reducing the range. If the issue persists, the sensor itself may be faulty and require replacement.
  • H
    hurleyrodneyAug 27, 2025
    What to do if T&S Plumbing Product continues to run?
    • C
      Crystal WolfeAug 27, 2025
      If your T&S Plumbing Product continues to run even after power has been disconnected, it could be due to debris in the solenoid valve preventing it from closing. Another possible cause is a faulty control module, which would need to be replaced.

Summary

Limited One Year Warranty

Exploded View EC-3100

Exploded View EC-3101

Exploded View EC-3102

Exploded View EC-3103

Exploded View EC-3106

Part Number Guide

EC-3100 & EC-3101 Electronic Faucets

Lists parts for EC-3100 and EC-3101 models.

EC-3102 & EC-3103 Electronic Faucets

Lists parts for EC-3102 and EC-3103 models.

EC-3106 Electronic Faucet

Lists parts for the EC-3106 model.

General Instructions

Tools Required For Installation of Faucets

Lists necessary tools for faucet installation.

Prior to Installation

Steps to take before beginning faucet installation.

Installation of ChekPoint Faucets

OPTIONAL ANTI-ROTATION FEATURE

Wall-Mount Model: EC-3101

Instructions for anti-rotation feature on EC-3101 wall-mount.

Deck-Mount Models: EC-3100 & EC-3102

Instructions for anti-rotation feature on EC-3100/3102 deck-mount.

Install Mixing Valve Assembly

Mount Control Module to Wall

FOR HOT AND COLD WATER SUPPLY APPLICATIONS

Sensor Cable and Supply Line Connections

TRANSFORMER OPTION

BATTERY OPTION

SENSOR RANGE SETUP

OPERATION

CARE AND CLEANING OF CHROME AND SPECIAL FINISHES

EC-3106 (MANUAL;AUTO OPERATION)

Sensor Module ByPass Operation (EC-3106 only)

FEATURES

AUTO-ADJUSTMENT SCAN PERIOD

Explanation of the auto-adjustable scan periods.

WATER FLOW CONTROL ADJUSTMENTS

How to adjust water flow using control module switches.

AUTO TIME-OUT ADJUSTMENT (SWITCHES 1-3)

Setting auto time-out for water shut-off using switches.

WATER SHUT-OFF DELAY ADJUSTMENT (SWITCHES 5 & 6)

Adjusting the delay for water shut-off after object removal.

AUTO-FLUSH (SWITCH 4)

Enabling or disabling the auto-flush feature.

LOW BATTERY DETECTION

POWER SAVING

ANTI-INTERFERENCE SYSTEM

Q&A

TROUBLESHOOTING GUIDE

B-2740 SERIES SINGLE LEVER FAUCETS

B-2740 Side Mount Mixer Assembly

Gooseneck Assembly for B-2741, B-2742 & B-2746

Gooseneck Assembly for B-2743, B-2744 & B-2749

B-2740 Side Mount Mixer Assembly

Gooseneck Assembly for: B-2741 B-2742 B-2746

Gooseneck Assembly for: B-2743 B-2744 B-2749

Installation of Side Mount Mixer (No.1) B-2740

Installation of Gooseneck Assembly, included in B-2741, B-2742 & B-2746 Assemblies

Installation of Gooseneck w; Side Spray Assembly, Included in B-2743, B-2744 & B-2749 Assemblies

EC-TMV & 5 EF-TMV Thermostatic Mixing Valve Installation Instructions

TOOLS NEEDED

Lists tools required for TMV installation.

INSTALLATION

Step-by-step instructions for installing the thermostatic mixing valve.

ADJUSTMENT

EC-HYDROGEN Installation Instructions

For ChekPoint Models with Below Deck Temperature Mixing Valves

Installation steps for EC-HYDROGEN with below deck mixing valves.

SENSOR RANGE SETUP

For ChekPoint Models with Above Deck Temperature Mixing Valves

T&S ChekPoint EC-3100 Specifications

General IconGeneral
BrandT&S
ModelChekPoint EC-3100
CategoryPlumbing Product
LanguageEnglish