6-4
OPERATING PROCEDURES
Models 345, 346, 349, 355
Operating Procedures
6
Place the draw handle slide over the opening in the
draw handle and the pivot pin. Secure the assembly
with screws.
Figure 6-12
9. Insert the spring into the front of the door spout.
Figure 6-13
10. Place the threaded cap on the end of the draw valve
cavity. Turn the cap clockwise until it is secure.
Figure 6-14
11. Install the prime plug. Place the two O-rings on the
prime plug and lightly lubricate.
Figure 6-15
12. Place the large O-ring into the door groove and lightly
lubricate.
Figure 6-16
Note: Every three months, discard the O-rings and
install new O-rings.
13. Install the front bearing. Do not lubricate the front
bearing.
Figure 6-17
11132
11131
11129
11130
11134