6-8
OPERATING PROCEDURES
Models 8752, 8756, and 8757
Operating Procedures
6
16. Slide the pump collar upwards into the grooves on
the side of the face plate and secure the air/mix
pump in place by slipping the retaining pin through
the crossholes of the pump collar.
Figure 6-32
Note: Alignment of the air/mix pump is extremely
important. Severe and costly damage may occur if it
is not properly aligned.
17. Lubricate both sides of the pressure switch
diaphragm.
Figure 6-33
18. Place the diaphragm on the front face of the pressure
switch housing. The lubricant will act as an adhesive
to hold the diaphragm in place.
Note: Do Not place the diaphragm in the pressure
switch cap.
19. Screw the cap onto the housing securely.
Figure 6-34
20. Repeat Steps 1 through 8 for the other side of the
machine on Models 8756 and 8757.
Apply the appropriate
Taylor approved food safe lubricant.