6-10
OPERATING PROCEDURES
Models 8752, 8756, and 8757
Operating Procedures
6
Sanitizing
1. Prepare a pail of approved 100 ppm sanitizing
solution (examples: 2-1/2 gal. [9.5 L] of Kay-5
®
or
2
gal. [7.6 L] of Stera-Sheen
®
). Use warm water and
follow the manufacturer’s specifications.
2. Place the pail of sanitizing solution inside the mix
cabinet.
3. Brush-clean the mix inlet tube with the long brush
and sanitizing solution.
Figure 6-36
4. Connect the free end of the flare line to the threaded
fitting on the mix inlet tube.
Figure 6-37
5. Install the pressure line. Attach the quick-disconnect
fitting of the pressure line to the other fitting on the
mix inlet tube just above the flare line and allow the
other end to hang free.
Figure 6-38
6. Insert the free end of the suction line and pressure
line into the pail of sanitizing solution.
Figure 6-39
7. Place the power switch in the ON position.
Figure 6-40