5-4
USER INTERFACE
Model C300
User Interface
5
BRL NOT COOLING—A freezing cylinder check has
been established for the AUTO mode of operation. If a
freezing cylinder enters the AUTO mode, the control will
check product temperature. After five minutes, it will
again check product temperature. If product temperature
does not drop in that 5-minute time span, the freezing
cylinder will shut down and this message will appear on
the fault screen. For this check to be valid, the product
temperature must be above 40°F (4.4°C).
BRL TEMP 2 HIGH—A maximum allowable product
temperature has been established to prevent product
from excessive heating. If the product exceeds 120°F
(49°C) for any reason (in any mode of operation), the
entire unit shuts down.
Faults, when corrected, are cleared from the FAULT
DESCRIPTION screen, with the following exception: BRL
NOT COOLING. This fault requires the operator to press
the OFF (<- -) key (when in the FAULT DESCRIPTION
screen) in order for the fault to discontinue.
To see if there is more than one fault in either freezing
cylinder, press the PRIME (+ + +) key. To return to the
operator menu, press the MENU (SEL) key once. To
return to the Main Screen, use the AUTO (- ->) key to
cycle to menu item A, then press the MENU (SEL) key.
Screen C—SET CLOCK
Use the AUTO (- ->) and OFF (<- -) keys to place the
cursor under the element to be set (hours, minutes,
month, day, or year). Use the PRIME (+++) and BEATER
(- - -) keys to increment or decrement the value. Press
the MENU (SEL) key to advance to the Daylight Saving
Time screen.
Note: The clock is programmed with military time.
This screen will appear if an invalid date is entered
(example: if the date entered exceeds the days of that
month).
This screen allows the Daylight Saving Time options. If
the Daylight Saving Time option is enabled, then the time
will be advanced by one hour at 2:00 a.m. on the first
Sunday in April, and will be retarded by one hour at 2:00
a.m. on the last Sunday in October.
Screen D—MANUAL DEFROST
This screen allows the operator to manually defrost the
left or right side of the unit.
Place the cursor under YES, press the MENU (SEL) key,
and the command will be executed.
FAULT DESCRIPTION
L: BARREL NOT COOLING
R: NO FAULT FOUND
CLR +++ SEL
FAULT DESCRIPTION
L: BARREL TEMP 2 HIGH
R: NO FAULT FOUND
CLR +++ SEL
SET CLOCK
14
60/52/0103:
<-- --> +++ --- SEL
SET CLOCK
14
70/13/2003:
INVALID DATE
SEL
DAYLIGHT SAVING TIME
ENABLE
DISABLE
LES>----<
MANUAL DEFROST
SEYEDISTFEL
NO
LES>----<

Other manuals for Taylor C300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Taylor C300 and is the answer not in the manual?

Taylor C300 Specifications

General IconGeneral
BrandTaylor
ModelC300
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals