OPERATING PROCEDURES
6-11
Model C300
Operating Procedures
6
Rinsing
1. To place the left cylinder in the Rinse mode, press the
MENU (SEL) key. Move the cursor by pressing the
AUTO (- ->) key until the third line indicates RINSE /
SANITIZE.
Press the MENU (SEL) key. Move the cursor under
“RINSE” by pressing the OFF (<- -) key twice.
2. Pressing the MENU (SEL) key will give you the
option for rinsing the left freezing cylinder. Move the
cursor under the word YES. Pressing the MENU
(SEL) key at this time will start the beater motor and
deliver water and CO
2
to the left cylinder.
3. Allow the rinse water to flow into the cylinder until it is
approximately 2/3 full. With a pail under the door
spout, open the draw valve and drain the rinse water.
Repeat this step until the rinse water being drawn is
clear.
4. Repeat steps 2 and 3 for the right side.
5. When draining is complete, press the OFF (<- -) key.
Cleaning
1. Prepare 1 gal. (7.6 L) of an approved cleaning
solution (examples: Stera Sheen or
Kay-5®). Use warm water and follow the
manufacturer's specifications.
Important! Make sure the cleaner is completely
dissolved.
2. Place the syrup line with the old syrup connector into
the pail of cleaner
3. To place the left freezing cylinder in the Sanitize
mode, press the MENU (SEL) key. Move the cursor
by pressing the AUTO (- ->) key until the third line
indicates RINSE / SANITIZE. Press the MENU (SEL)
key. Move the cursor under the word SANITIZE.
Pressing the MENU (SEL) key will give you the
option to sanitize the left cylinder. Move the cursor
under the word YES. Pressing the MENU (SEL) key
at this time will start the flow of cleaner/sanitizer
through the syrup system into the freezing cylinder.
4. Repeat steps 1 through 3 for the right side freezing
cylinder.
5. Open the prime plugs. Allow each cylinder to fill
approximately 2/3 full. Close each prime plug.
6. Continue filling the freezing cylinders with sanitizing
solution until the solution purges out of each vent,
and begins draining into the front drip tray.
The relief valves are located at the top of each
mix tank. Press the OFF (<- - ) key
7. Press the BEATER (- - -) key to agitate the solution in
each freezing cylinder for five minutes.
OPERATOR MENU
ABCDEFGH
I
RINSE / SANITIZE
LES>----<
RINSE / SANITIZE
RINSE SANITIZE EXIT
----
LES>----<
RINSE
LEFT SIDE YES NO
---
LES>----<
RINSE
RIGHT SIDE YES NO
---
LES>----<
RINSE / SANITIZE
RINSE SANITIZE EXIT
-----
LES>----<
SANITIZE
LEFT SIDE YES NO
---
LES>----<