OPERATING PROCEDURES
6-7
Model C300
Operating Procedures
6
7. Pressing the MENU (SEL) key will give you the
option for sanitizing the left freezing cylinder. Move
the cursor under the word “YES”. Pressing the MENU
(SEL) key at this time will start the flow of sanitizing
solution into the left freezing cylinder.
8. Repeat steps 6 and 7 for the right side freezing
cylinder.
9. Open the prime plugs. When sanitizing solution fills
the freezing cylinders approximately 2/3 full, close
the prime plugs.
Figure 6-25
10. Continue filling the freezing cylinders with sanitizing
solution until the solution purges out of the relief
valve at the top of the mix tank, and begins draining
into the front drip tray. Press the OFF (<- - ) key.
11. Press the BEATER (- - -) key. Agitate the solution in
the freezing cylinders for 5-minutes.
Figure 6-26
12. With a pail beneath the door spouts, open the draw
valves and drain all the solution from the freezing
cylinders. Press the OFF (<- -) key and close the
draw valves.
Figure 6-27
13. Disconnect the syrup connectors in the sanitizing
solution.
Priming/Brixing
1. Connect the syrup line to the bag-in-box (BIB) syrup.
2. Remove the drip tray, splash shield, and lower front
panel to gain access to the syrup sampling valves.
3. Open the prime plug.
RINSE / SANITIZE
RINSE SANITIZE EXIT
-----
LES>----<
SANITIZE
LEFT SIDE YES NO
---
LES>----<
SANITIZE
RIGHT SIDE YES NO
---