8-2
TROUBLESHOOTING GUIDE
Model C300
Troubleshooting Guide
8
8. Leakage from
rear drip pan(s)
into front drip
tray.
a. Seal or O-ring on drive shaft is
worn, missing, or incorrectly
installed.
a. Replace or install correctly on
drive shaft.
6-1
b. Worn rear shell bearing. b. Contact a service technician. - - -
9. Excessive mix
leakage from
door spout.
a. Inadequate lubrication of draw
valve O-rings.
a. Lubricate properly. 6-3
b. Wrong type lubricant on draw
valve O-rings.
b. Use food grade lubricant
(example: Taylor Lube HP).
6-1
c. Worn or missing draw valve O-
rings.
c. Replace or install O-rings on
draw valve.
6-3 / 9-1
10. Unable to adjust
brix.
a. Syrup lines need to be cleaned
and sanitized.
a. Clean and sanitize syrup lines. - - -
b. Blocked flow control. b. Contact a service technician. - - -
11. Lack of syrup
being supplied
to machine.
a. Loss of CO
2
to propel syrup. a. Contact a service technician. - - -
b. Clogged or kinked syrup lines. b. Sanitize syrup lines regularly. If
kinked, repair or replace.
- - -
Problem Probable cause Remedy Page ref