SERVICE
MANUAL
Model C712 & C713
Soft Serve Freezers
6/15/05 (Original Publication)
(Updated 7/31/2018)
Original Service Instructions
062179-S

Table of Contents

Other manuals for Taylor c713

Questions and Answers

  • J
    Jose FarleyAug 26, 2025
    What to do if the product from my Taylor c713 is too soft?
    • R
      Robin McmillanAug 26, 2025
      If your Taylor Freezer is dispensing product that is too soft, consider the following possible causes: * Insufficient air space around the machine. Ensure a minimum of 3” clearance on all sides and install the deflector. * Worn scraper blades. Replace the scraper blades. * Dirty air-cooled condenser. Clean monthly. * Outdated mix. Use fresh mix. * Refrigerant shortage. Locate and repair the leak. * Product viscosity set too warm. Adjust the product viscosity. * Incorrect usage of the mix feed tube (C713). Follow the correct feed tube procedures and use of the air orifice.
  • R
    Rachel HumphreyAug 25, 2025
    Why is the head pressure too high in my Taylor c713 Freezer?
    • K
      Kyle RamseyAug 26, 2025
      If the head pressure of your Taylor Freezer is too high, it could be due to several reasons: * The condenser might be dirty; if so, clean it. * The water valve might be out of adjustment or restricted; if so, check the adjustment and the water supply. * There might be insufficient air space around the machine; if so, ensure sufficient air space. * There might be a refrigerant overcharge; if so, correct the refrigerant charge. * The blower might be faulty; if so, replace the blower.
  • C
    clarkdennisAug 23, 2025
    Why does my Taylor Freezer run long cycles and shut off on the safety timer?
    • L
      Lori SnyderAug 25, 2025
      If your Taylor Freezer is operating for extended periods and cycling off on the 11-minute safety timer, the issue could stem from several factors: * A dirty condenser. Clean the condenser. * Worn scraper blades. Replace the scraper blades. * A shortage of refrigerant. Repair the leak and recharge the machine. * Air in the system. Purge and recharge the system. * High overrun product (C712). Check the pump operation for the correct air/mix ratio.

Summary

Section 1: Introduction

Safety

Essential safety precautions and warnings for operating and servicing the freezer.

General Installation Instructions

Guidelines and procedures for safely and correctly installing the freezer unit.

Section 3: Troubleshooting

General Troubleshooting Guide

Common problems, probable causes, and remedies for freezer operation issues.

Electrical Troubleshooting Guide

Guide for diagnosing electrical issues based on component operation in different modes.

C712;C713 Electrical Troubleshooting Guide

Specific electrical troubleshooting steps for C712 and C713 models.

Bacteria Troubleshooting

Guidance on preventing and addressing bacteria contamination issues in the freezer.

Taylor c713 Specifications

General IconGeneral
TypeSoft Serve Freezer
Number of Flavors2
Refrigeration SystemAir or Water Cooled
Separate Hopper RefrigerationYes
Indicator LightsYes
Water CooledYes
Electrical208-230V, 1PH, 50/60Hz
MotorTwo 1.5 HP
Air Cooled Minimum Clearance6" on both sides