EasyManuals Logo

Taylor C722 User Manual

Taylor C722
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #41 background imageLoading...
Page #41 background image
OPERATING PROCEDURES
6-9
Model C722
Operating Procedures
6
5. Important: Install the pump end of the mix feed
tube and secure it with the cotter pin. Failure to
follow this instruction could result in sanitizer
spraying on the operator. (
See Figure 6-36.)
Figure 6-36
6. Prepare another pail of cleaning/sanitizing solution
with an active chlorine concentrate of
100 ppm–200 ppm.
Important! Use warm water and follow the
manufacturer's specifications.
7. Pour the sanitizing solution into the mix hopper.
8. Brush the exposed sides of the hopper.
9. Place the power switch in the ON position.
10. Press the Wash symbol . This will cause the
sanitizing solution in the freezing cylinder to be
agitated. Wait at least 5 minutes before proceeding
with these instructions.
11. With an empty pail beneath the door spouts, raise the
prime plug and press the Mix Pump symbol.
12. When a steady stream of sanitizing solution is flowing
from the prime plug opening in the bottom of the
freezer door, open the draw valve. Momentarily open
the center draw valve to sanitize the center door
spout. Draw off the remaining sanitizing solution.
13. Once the sanitizer stops flowing from the door spout,
press the Wash and Mix Pump symbols
and close the draw valve.
Important! The machine must not be placed in
Auto until all sanitizing solution has been
removed from the freezing cylinder and proper
priming procedures have been completed. Failure to
follow this instruction may result in damage to the
freezing cylinder.
Note: Make sure your hands are clean and
sanitized before proceeding with these instructions.
14. Place the agitator on the agitator driveshaft housing.
Figure 6-37
Note: If the agitator should stop turning during
normal operation, with sanitized hands, remove the
agitator from the agitator driveshaft housing and
brush-clean it with sanitizing solution. Install the
agitator back onto the agitator driveshaft housing.
Repeat steps 1 through 14 for the other side of the
machine.
Priming
Note: Use only fresh mix when priming the freezer.
1. Place an empty pail beneath the door spouts. With
the prime plug in the up position, pour 2-1/2 gal.
(9.5 L) of fresh mix into the mix hopper and allow it
to flow into the freezing cylinder.
2. Open the draw valve to remove the sanitizing
solution. When only fresh mix is flowing, close the
draw valve.
12314
12182

Other manuals for Taylor C722

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Taylor C722 and is the answer not in the manual?

Taylor C722 Specifications

General IconGeneral
BrandTaylor
ModelC722
CategoryFreezer
LanguageEnglish

Related product manuals