EasyManuals Logo

TC Electronic TC 2290 User Manual

TC Electronic TC 2290
115 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #88 background imageLoading...
Page #88 background image
Spec
Min/max
Fac.
Preset/
Name/
No.
Value
Default
giobal
Function
37
0-9999
0
global
Reset
-
If
you
write
'T
in
this
spec.
no.
the
factory
presets
80-99
are
restored
at
the
next
power
on/off
sequence.
Otherwise
if
the
number
‘'2290'
is
not
the
value
of
this
spec.
no,
a
total
reset
of
the
TC
2290
is
performed
at
next
power
on/off.The
reset
includes
all
presets
and
special-nos.
are
set
to
the
factory
default
values.
Note
that
at
the
following
power-up
the
errorno.
'13'
is
shown
(presets
lost)
until
you
write
‘O'
in
the
spec.no
23
to
tell
TC
2290
that
you
are
aware
that
presets
are
lost.
38
1000-
9999
1023
global
Max.Dlytime
sets
max
delaytime
when
pressing:
<LEARN>
~
when
sampling
(repeat/hold)
how
long
the
repeating
sample
is.
Turn
off/on
power
before
active.
40-48
0-199
31
global
Assign
Key
A
String,
default
is
<PRESET
UP>.
(See
section
for
programming
assign
keys).
50-58
0-199
32
global
Assign
Key
B
String,
default
is
<PRESET
DOWN>.
(See
section
for
programming
assign
keys).
The
numbers
60-99
are
used
for
four
remote
assign
switches,
as
used
with
the
TC
0050
Remote
Switch
Panel.
You
can
also
make
remote
switches
yourself,
see
the
2290-apn.04
note
'How
to
make
remote
switches’.
60-68
0-199
85
global
Remote
Assign
Key
1
String,
default
is
<DELAY
ON>.
(See
section
for
programming
assign
keys).
70-78
0-199
36
global
Remote
Assign
Key
2
String,
default
is
<LAST
PRESET>.
(See
section
for
programming
assign
keys).
80-88
0-199
31
global
Remote
Assign
Key
3
String,
default
is
<PRESET
UP>.
(See
section
for
programming
assign
keys).
90-98
0-199
32
global
Remote
Assign
Key
4
String,
default
is
<PRESET
DOWN>.
(See
section
for
programming
assign
keys).
Note
that
if
the
special
is
‘in
preset’
it
means
that
there
are
100
values,
one
individual
value
for
each
preset.
If
the
special
no.
is
‘global’
the
parameter
is
common
to
all
presets.
Calling
a
spec.no
other
than
the
above
will
result
in
error
#1.
Attempts
to
enter
‘out
of
range’
spec.
values
will
result
in
error
#2.
(The
spec.nos
from
25
and
up
are
new
or
changed
as
compared
to
lower
EPROM
version
#}

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TC Electronic TC 2290 and is the answer not in the manual?

TC Electronic TC 2290 Specifications

General IconGeneral
BrandTC Electronic
ModelTC 2290
CategoryComputer Hardware
LanguageEnglish

Related product manuals