Air Conditioner Service Manual
2
2. TECHNICAL SPECIFICATION
Model
TAC-09CHSA/XA71
INVERTER
TAC-12CHSA/XA71
INVERTER
TAC-18CHSA/XA71
INVERTER
TAC-24CHSA/XA71
INVERTER
Type
heating pump
heating pump
heating pump
heating pump
Control type
remote
remote
remote
remote
Rated cooling capacity
9000(3412-11500)
12000(5200-13500)
18000(5500~20000)
24000(6500~26000)
2640(1000~3370)
3520(1520~3950)
5280(1610~5860)
7050(1800~7500)
Rated heating capacity
9500(3412-12600)
12500(5500-14500)
18500(6500~24000)
24500(8500~28000)
2780(1000~3690)
3660(1520~4240)
5420(1320~7030)
7200(2110~8500)
EER for cooling
3.22
3.23
3.25
3.24
COP for heating
3.62
3.61
3.63
3.62
Moisture removal
1
1.2
1.8
2.2
Pressure
High(DP)
4.5
4.5
4.5
4.5
Low(SP)
1.9
1.9
1.9
1.9
Indoor noise level at
cooling
SUPER
39
39
44
48
High
35
36
43
46
Med
32
31
36
42
Low
28
28
33
39
MUTE
26
25
30
35
Outdoor noise level
50
50
53
53
Electrical Data
Power supply
220-240V/50Hz
220-240V/50Hz
220-240V/50Hz
220-240V/50Hz
Voltage Range
170-265
170-265
170-265
170-265
Rated current
Cooling
3.8(1.8~7.2)
5.0(1.8~8.0)
7.5(2.4~10.2)
10.0(2.8~10.6)
Heating
3.6(1.8~7.5)
4.7(1.8~8.8)
6.9(2.1~11.1)
9.2(3.0~12.1)
Rated input
Cooling
820(320~1250)
1090(320~1550)
1620(520~2300)
2170(620~2380)
Heating
770(320~1350)
1010(320~1650)
1490(470~2450)
1990(660~2650)
Max Current
Cooling
7.2
8.0
10.2
10.6
Heating
7.5
8.8
11.1
12.1
Max Power input
Cooling
1250
1550
2300
2380
Heating
1350
1650
2450
2650
Refrigerating System
Refrigerant/Charge
R410A/520g
R410A/650g
R410A/830g
R410A/1650g
Compressor
Model
39A23MYJ&FJKD
39A23MYJ&FJKD
ASD113RKPA6JT1
ATN150D42UFZ
MFG
RECHI
RECHI
HIGHLY
GMCC
Type
Rotary
Rotary
Rotary
Rotary
Fan System
Indoor air
circulation(Cooling/Heating)
430/430
550/550
750/750
1000/1000
Indoor fan type
Cross flow
Cross flow
Cross flow
Cross flow
Indoor fan speed H/M/L
Cooling
1100/1000/900/
800/700
1250/1150/950/850/6
00
1300/1250/1000/900/75
0
1200/1100/1000/900/70
0
Heating
1100/1050/950
/850/800
1250/1150/1000
/900/800
1300/1250/1000
/900/750
1200/1100/1000
/900/700
Dry
700
700
900
900
Sleep
700
700
900
900
Indoor fan motor output
20
20
25
45
Outdoor fan type
Propeller
Propeller
Propeller
Propeller
Outdoor fan speed
860
860
860
860/700
Outdoor fan motor output
25
25
25
45
Connections
Connecting Pipe
Gas
Φ9.523/8''
Φ9.523/8''
Φ9.523/8''
Φ12(1/2'')
Liquid
Φ6(1/4'')
Φ6(1/4'')
Φ6(1/4'')
Φ6(1/4'')
Connecting Wiring
Size x Core
number
4×1.5
4×1.5
4×0.75
4×0.75
Drainage Pipe
O.D 16mm
O.D 16mm
O.D 16mm
O.D 16mm
Net dimensions
(W x H x D)
Indoor
698×255×190
777×250×201
910×294×206
1010×315×220
Outdoor
754×300×552
754×300×552
817×328×553
886×357×605
Packing dimensions
(W x H x D)
Indoor
764×325×257
840×315×260
979×372×277
1096×390×297
Outdoor
798×321×575
798×321×575
858×321×585
930×380×635