EasyManua.ls Logo

TDK-Lambda LS Series - Page 22

TDK-Lambda LS Series
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...

All specifications are subject to change without notice.
LS
Series
LS75-3.3, -5
6045 70
Mounting C
Output Derating Vs Ambient Temperature
Load (%)
Ambient Temperature (ºC)
120
100
80
60
40
20
0
-25 0 25 50 75 100
70
Mounting
A, B & D
LS75-12, -15, -24, -36 & -48
Output Derating Vs Ambient Temperature
Load (%)
Ambient Temperature (ºC)
120
100
80
60
40
20
0
-25 0 25 50 75 100
50
70
60 70
Mounting
A, B & D
Mounting C
LS100 -3.3, -5
50
40 45 70
Output Derating Vs Ambient Temperature
Load (%)
Ambient Temperature (ºC)
120
100
80
60
40
20
0
-25 0 25 50 75 100
Mounting
A & B
Mounting
C & D
LS100 -12, -15, -24, -36 & -48
45 70
Output Derating Vs Ambient Temperature
Load (%)
Ambient Temperature (ºC)
120
100
80
60
40
20
0
-25 0 25 50 75 100
50
Mounting
A & B
Mounting
C & D
LS150 -3.3, -5
Mounting A
Mounting
B , C & D
Output Derating Vs Ambient Temperature
Load (%)
Ambient Temperature (ºC)
120
100
80
60
40
20
0
-25 0 25 50 75 100
50
4030 70
LS150 -12, -15, -24, -36 & -48
Mounting A
Mounting
B , C & D
Output Derating Vs Ambient Temperature
Load (%)
Ambient Temperature (ºC)
120
100
80
60
40
20
0
-25 0 25 50 75 100
70
40 70
(2) Output Derating versus Input Voltage (Convection
Cooling)
LS100 -3.3, -5, -12, -15, -24, -36 & -48
Load (%)
Vin (VAC)
120
100
80
60
40
20
0
88 115 230 264
Output Derating Vs Input Voltage
NOTE : LS25, LS35, LS50, LS75 & LS150 series do not require
Input Voltage Derating.
󱫂
Mounting Method
(1) This is convection cooling type power supply. In consider-
ation of the heat radiation and safety, please keep a distance
of more than 15mm between the power supply and the pe-
ripheral parts. When lining up multiple units, please make
sure to place them 15mm or more apart from each other.
(2) Maximum allowable penetration of mounting screwsinto the
power-supply is 5mm except LS25 (4mm).
(3) Recommended torque for mounting screws of LS25 to
LS150 (M3 screw) : 0.49 N·m (5.0 kgf·cm).