・All specifications are subject to change without notice.
LS
25
MODEL
ITEMS/UNITS
LS25-3.3 LS25-5 LS25-12 LS25-15 LS25-24 LS25-36 LS25-48
Input
Voltage Range (*2)
V
AC88 to 264 or 125 to DC373 (Withstand AC300 Surge for 5 seconds)
Frequency (*2) Hz 47-63
Efficiency(230VAC)(typ) (*1)
% 75 79 83 84 85
Current(115/230VAC)(typ) (*1)
A 0.7 / 0.4
Inrush Current(typ) (*3)
A 30A at 230VAC, Ta=25°C (Cold Start)
Leakage Current (*10)
mA < 1mA at 230VAC
Output
Nominal Voltage
VDC
3.3 5 12 15 24 36 48
Maximum Current
A 6 5 2.1 1.7 1.1 0.75 0.57
Maximum Power
W 19.8 25 25.2 25.5 26.4 27 27.36
Maximum Line Regulation (*5)(*6)
mV 20 48 60 96 144 192
Maximum Load Regulation (*5)(*7)
mV 40 96 120 192 288 384
Temperature Coefficient
Less than 0.02%/°C
Maximum Ripple & Noise (*1)(*4)
mVp-p
80 120 150 200
Hold-up Time(115/230VAC)(typ) (*1)
ms 14 / 80
Voltage Adjustable Range
VDC
2.85 to 3.6
4.5 to 5.5
10.8 to 13.2 13.5 to 16.5
22 to 27.6
32 to 40 42 to 54
Function
Over Current Protection (*8)
A > 110% rated output current
Over Voltage Protection (*9)
VDC
> 120% nominal output voltage
Series Operation
Possible
Environment
Operating Temperature (*11)
°C - 25 to + 70 (Refer to Output Derating Curve)
Storage Temperature
°C - 40 to +85
Operating Humidity
%RH
20 to 90 (No dewdrop)
Storage Humidity
%RH
10 to 95 (No dewdrop)
Vibration
At no operating, 10 - 55Hz (sweep for 1min)
19.6m/s² Constant, X, Y, Z 1hour each.
Shock(In package)
Less than 196.1m/s²
Cooling
Convection cooling
Isolation
Withstand Voltage
Input - Output : 3.0kVAC (20mA), Input - FG : 1.5kVAC (20mA)
Output - FG : 500VAC (100mA) for 1min.
Isolation Resistance
Input - FG, Input - Output and Output - FG: More than 100M
Ω
(500VDC) at 25
°C
and 70%RH
Standards
Safety Standards Approved by UL60950-1, EN60950-1, IEC60950-1
PFHC
Built to meet IEC61000-3-2, -3
EMI
Built to meet EN55011/EN55022-B, FCC-B
Immunity
Built to meet EN61000-4-2 (Level 2,3), -3 (Level 3), -4 (Level 3),
-5 (Level 3), -6 (Level 3), -8 (Level 4), -11
Mechanical
Weight(typ) g 170
Size (W×H×D)
mm 79 x 51 x 28 (Refer to Outline Drawing)
(*1) At Maximum Output Power, nominal input voltage, Ta = 25
°C
.
(*2) For cases where conformance to various safety specs ( UL, CSA, EN ) are required, to be described as 100 - 240VAC, 50 / 60Hz on name plate.
(*3) Not applicable for the in-rush current to Noise Filter for less than 0.2mS.
(*4) Ripple & noise are measured at 20MHz by using a 300mm twisted pair of load wires terminated with a 0.1uF film capacitor and a 47uF
electrolytic capacitor.
(*5) Measure line & load regulation at output terminal M3 tapped point.
(*6) 88 - 264VAC, constant load.
(*7) No load - Full load (Maximum power ), constant input voltage.
(*8) Current limit with automatic recovery.
Avoid to operate at overload or dead short for more than 30 seconds.
(*9) Over voltage clamp by zener diode, hiccup mode.
(*10) Measured by each measuring method of UL and EN (at 60Hz), Ta = 25
°C
.
(*11) Refer to Output Derating Curve (PA580-01-02_) for details of output derating versus ambient temperature.
(*12) All parameters NOT specifically mentioned are measured at 230VAC input, rated load and Ta = 25
°C
.
LS25 Specifications