4-10
Installation
To reduce the default large volume to . and the small
volume to . litres, the tank water level lever above the
filling valve must also be moved to the lowest mark on the
overflow.
Removing the drain valve
Totake outthe filling valve, open the splash guard with the
actuation block. Press the hold-down device downwards
as shown in the illustration and remove it from the tank.
Now pull the filling valve upwards out of the valve seat,
snap o the top part and take it out.
After removing the drain valve, the valve seat can be
removed by pulling it upwards.
Throttle set
If the flushing of a toilet ceramic is not adequate, the flush-
ing pressure can be reduced or increased with the help of
the throttle set.
The throttle set includes four dierent throttles:
• Blue: Diameter mm (%)
• Grey: Diameter mm (%)
• Black: Diameter mm (%)
• White: Diameter mm (%)
Reducing the flushing pressure
The throttle set can be used to reduce the flushing pres-
sure if water sprays out of the toilet ceramics To control the
flushing pressure, a throttle with a smaller internal diame-
ter can be used.
Increasing the flushing pressure
If the toilet ceramics are not being cleaned correctly, the
flushing pressure for cm cisterns can be subsequently
increased. To increase the flushing pressure, install a throt-
tle with a larger internal diameter or remove the inserted
throttle.
The flush flow throttle can be easily installed in the valve
seat of the drain valve.
Ø 28 mmØ 29 mmØ 30 mmØ 32 mm