4-17
U 1 TECE urinal flush valve
The mechanical cartridge is simply screwed into the hous-
ing.
Install the electric cartridge (do not insert with a tool!) and
tighten the screws by hand.
Note:
When installing the electronic cartridge, it is particularly
important to place it in the correct position. As can be
seen on the right-hand side of the diagram, the position
also depends on the installation situation of the flush
valve housing: Horizontal housing = shut-o on the left,
electronics on the right; vertical housing = shut-o at the
top, electronics at the bottom. If the cartridge is installed
incorrectly, it may happen that the function is initially given
but malfunctions occur after a certain time.
Programming the urinal infrared electronics
After installing the electrical supply, the electronics can
be programmed within one hour using the magnetic key
supplied. In order to change the program, the power
supply must be interrupted. Thanks to a memory module,
the previously set programme is always active despite the
power cut.
Approximately five seconds after being connected to the
power supply, TECE electronics can be programmed in the
first minutes. Each configurable function is assigned a
position.
Position Function
1 Pause function “o”
2 Pause function “on”
3 Flushing time 2 s
4 Flushing time 2.5 s
5 Flushing time 3 s
6 Flushing time 3.5 s
7 Flushing time 4 s
8 Flushing time 5 s
9 Flushing time 6 s
10 Flushing time 8 s
11 Flushing time 10 s
12 Pre-rinsing “o”
13 Pre-rinsing 0.5 s
14 Pre-rinsing 1 s
15 Pre-rinsing 2 s
16 Hygiene flush “o”
17 Hygiene flush 24 h
18 Hygiene flush 255 h
19 Sensor sensitivity “low”
... ...
23 Distance “standard”
24 Distance “short”
25 Distance “long”
... ...
28 Factory setting
29 Urinal covers “o”
30 Urinal covers “on”
= Factory setting
Programming list for the urinal electronics
In programming mode, the electronics can be set with the
magnetic key. In standard mode, only the cleaning function
can be activated with this key.
• Cleaning function:
When cleaning the urinal, automatic flushing is generally
not required as the cleaning agent needs time to take
eect. For this reason, flushing can be delayed by
minutes.
• Pre-flush (optional):
(Duration – seconds) Briefly humidifies the ceramics