4-20
U 2 TECEfilo urinal flush valve
The U2 TECE urinal flusher is suitable for installation in dry
and brick-wall constructions. For dry-wall constructions,
installation is performed together with the TECE urinal
module. The transformer is already integrated into the two
shell elements which means that it is suitable for direct
230 V connection.
U2 TECEbox urinal flush valve
housing for brick-wall construction
(9370040)
Compatible with the V mains
and the . V battery versions.
The transformer for V mains
operation is already integrated.
210
80
200
130
min. 83
TECEprofil urinal module with U2
flush valve housing (9320013)
Compatible with the V mains
and the . V battery versions.
The transformer for V mains
operation is already integrated.
min. 75
0 -200
500
1120-13000
max. 1070
500-910
450-770
200-600
OKFF
min. 14
80
130
1153-1333
TECEfilo installation frame for
flush-mounted installation, for
dry-wall constructions only
(9242040/41/42)
The TECEfilo plastic electronics,
like the glass ones, can be mount-
ed with the TECEfilo installation
frame for flush-mounted installa-
tions in dry-wall structures.
170
157
110
107
220
160
U 2 urinal flush valve assembly instructions
Note: This section provides instructions for the essential
points of installation. The notes are thus explained sections
from the overall assembly procedure. The entire installa-
tion procedure is shown in the assembly instructions for
the corresponding items.
The U flush valve housing can be installed in dry-walls
and brick-walls. For better coordination of the trades, the
transformer is already integrated into the flusher housing.
The transformer can therefore be directly connected with a
V cable.
It is also possible to loop the connection.
R 1/2 "
!
To connect the pipe, hold the connection housing as
shown in ill. .