power source. Carefully avoid touching the victim or clothing. Call for medical help immediately.
2.2. Operating Safeguards
Load Impedance
Technalogix FM equipment functions with a 50-ohm load impedances. It is imperative you maintain 50-
ohm impedances throughout your system for your equipment to provide maximum power transfer to the
antenna and decreased reflected power heading back towards the amplifier pallets. Failure to provide a
50-ohm path throughout the system may result in damage to your equipment. Before anything is turned
on, ensure that there is a 50-ohm path from the output of each stage to the input of the next, all the way
to the antenna.
Operating Warnings
Our FM equipment is designed to reliably generate a specific RF output power level. Failing to adhere to
overdriven amplifier, high reflected power, and high temperature, and other warnings can decrease the
reliability of your system and may result in damage to the unit. If you need to transmit to a little larger
coverage, you are better off increasing antenna gain, and more importantly, antenna height above
average terrain. On FM broadcast frequencies, insufficient antenna height puts an upper limit on your
range, regardless of power levels, as the distance from your antenna to the radio horizon is limited.
The radiated power from the cabinet of this device is below the Industry Canada radio
frequency exposure limits. The device should be used in such a manner that the potential
for human contact with the antenna during normal operation is minimized.