1000BASE-T1 SPY mini User Manual
Digital Trigger Input / Output 1
Digital Trigger Input / Output 2
Signal Ground Reference
Signal Ground Reference
Signal Ground Reference
Digital Trigger Input / Output 3
Digital Trigger Input / Output 4
Digital Trigger Input / Output 5
Digital Trigger Input / Output 6
Table 2—3: Pinning information SubD9 Connector
Digital Trigger Output:
Digital Trigger Output Voltage is 3.3 Volt Level with a 4.7 KOhms pull-up resistor
Active Low. Drive Strength 20 mA
Digital Trigger Input:
Digital Trigger Input is a Voltage 3.3 Volt Level with a 4.7 KOhm pull-up resistor
Active LOW.
Note: The Trigger Connector has no function on firmware version 1.2.1.
2.1.3 RJ45 Ethernet connectors
There are two RJ45 Standard Ethernet connectors of the front side for Gigabit
Ethernet.