Operation & Maintenance Manual
CD-135 / CD-155
OM-02-02
Chapter:
Issue:
Issue date:
Page:
Content:
02-OM-06-02
4
30.07.2014
42
74
Revision no.:
Revision date:
7
20.07.2016
d) Conduct the engine Ground run according to the
operating manual.
e) Menu FADEC => Stop RTLF. The following screens will
appear:
Note: During the ground run, the user should verify that engine
parameters are to spec.
Compare the values of Map to MapTar, Prop RPM to PrSpdTar
and PRail to PRaTar to determine any discrepancy.
- Manifold Pressure (MAP): Compare MAP to MAPTar.
Deviation must be within a tolerance of 75 mbar.
- Propspeed (Prop RPM): Compare PropRPM to PrSpdTar.
Deviation must be within a tolerance of +/-50 RPM.
- Fuel Pressure (P-Rail): Compare PRail to PRaTar. Deviation
must be within a tolerance of +100/-70 bar.
Fig. 6.30 FADEC read-out - Stop Real Time Log File