Content:
02-OM-04-02
4
30.07.2014
7
10
2
02.09.2015
4.4.3 FADEC-Reset (from Software 2.7 on and following)
In case of a FADEC-warning, one or both FADEC warning lamps
are flashing. If the "FADEC" test button then is pressed for at
least 2 seconds, the following possibilities will occur:
Temporary failure
The active warning lamps will extinguish if it is a LOW category
warning and a temporary, not steady, failure.
In case of a temporary failure the FADEC light will illuminate after
the ignition has been switched off and on.
Steady failure or high category failure
The active warning lamps will illuminate steady if it is a steady
failure or high category failure.
WARNING: If a FADEC-warning occurred, contact your service center! Next
flight is not permitted!
WARNING: If a FADEC-warning occurred, contact your service center! Next
flight is not permitted!