4
30.07.2014
1
10
2
06.06.2016
3 Technical Data
3.1 Dimensions and Weights
Bore..............................................................................83.00 mm
Stroke...........................................................................92.00 mm
Cylinder spacing (center to center) ..............................90.00 mm
Displacement total........................................................ 1991 cm
3
Displacement (per cylinder) ........................................... 498 cm
3
Compression ratio.................................................................18:1
Firing order....................................................................... 1-3-4-2
Weight (dry).......................................................................134 kg
3.2 Performance Data
CD-135 (TAE 125-02-99)
Max. takeoff power......................................... 99 kw at 2300 rpm
Max. continuous power .................................. 99 kw at 2300 rpm
Recommended cruise power ......................... 71 kw at 2010 rpm
Best Economy................................................ 71 kw at 2010 rpm
CD-155 (TAE 125-02-114)
Max. takeoff power....................................... 114 kw at 2300 rpm
Max. continuous power ................................ 114 kw at 2300 rpm
Recommended cruise power ......................... 97 kw at 2010 rpm
Best Economy................................................ 97 kw at 2010 rpm
Note: All speed-related data in the operation and maintenance manual
refer to propeller speeds if not otherwise explicitly specified as
engine speeds.
Note: The performance and operational data refer to sea level at 15°C
and 0% relative humidity.