Operation & Maintenance Manual
CD-135 / CD-155
OM-02-02
Revision no.:
Revision date:
Chapter:
Issue:
Issue date:
Page:
Content:
02-OM-06-02
4
30.07.2014
27
74
7
20.07.2016
4. Attach the new o-ring to the filter cap. See Fig. 6.14.
5. Remount the filter cap and tighten it to the specified
tightening torque.
Tightening Torque:
30 Nm
6. Preset the proportional pressure reducing valve (refer to
Chapter 72-10.16 of RM-02-02).
7. Secure the gearbox oil filter cap with a locking wire.
See Fig. 6.15.
8. Do an Engine Test run according to Annex 4 of this Chapter.
9. Do a visual inspection and a check for leaks.
10. Check the gearbox oil level according to Annex 9 of this
Chapter.
Note: Make sure that the spring in the filter cap is fixed.