c) Follow the instructions on the screen, performing the
engine ground run according to Chapter 4, Section
4.4.2, Page 5 of this Manual. Press Continue. The
following screen will appear:
Fig. 6.34 FADEC read-out - Perform engine ground run
Note: During the ground run, the user should verify that engine
parameters are to spec.
Compare the values of Map to MapTar, Prop RPM to PrSpdTar
and PRail to PRaTar to determine any discrepancy.
- Manifold Pressure (MAP): Compare MAP to MAPTar.
Deviation must be within a tolerance of 75 mbar.
- Propspeed (Prop RPM): Compare PropRPM to PrSpdTar.
Deviation must be within a tolerance of +/-50 RPM.
- Fuel Pressure (P-Rail): Compare PRail to PRaTar.
Deviation must be within a tolerance of +100/-70 bar.