EasyManua.ls Logo

Technify Motors CD-135 - Annex 14: Coolant Exchange Procedure

Technify Motors CD-135
152 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation & Maintenance Manual
CD-135 / CD-155
OM-02-02
Revision no.:
Revision date:
Chapter:
Issue:
Issue date:
Page:
Content:
02-OM-06-02
4
30.07.2014
65
74
7
20.07.2016
Annex 14 Exchanging the Coolant
1. Draining the coolant:
Open the clamp on the lower hose of the water
radiator, disconnect the hose and allow the coolant to
drain into a prepared collecting container.
Open the clamp on the lower hose of the heat
exchanger, disconnect the hose and allow the coolant
to drain into a collection container.
Open the drain plug. Allow the coolant to drain into a
collection container.
After draining reinstall and tighten the drain plug.
Tightening Torque:
30 Nm
Reconnect the lower hoses of the water radiator and
the heat exchanger. Tighten the clamps.
2. Filling up new coolant:
Fill up the cooling system with coolant according to
IM-02-02 Chapter 4 by opening the coolant filler.
Close the cover of the coolant filler.
Perform a test run according to
Chapter 4, Section 4.4.2, Page 5 of this Manual.
Check the cooling system for leaks according to
Annex 3 of this Chapter.
Allow the engine to cool down.
Check coolant level.
WARNING: Risk of scalding! The cooling system may be pressurized.
Carefully release the pressure before opening the drain plug.
CAUTION: Do not drain the coolant if its temperature is above 40°C.