Error code
1st level
troubleshooting
Remedial action
Error code 7: DATAMATRIX
error.
Problem in calculating the
coding of the data matrix
Delete and recreate the data
matrix, checking the data and
settings to encode.
Error code 8: Stylus short-
circuit.
The striker unit cable has been
damaged.
Check the condition of the
striker unit cable and restart
the controller.
The striker unit connector has
been damaged.
Check the striker unit
connector and restart the
controller.
The marking head cable has
been damaged.
Check the condition of the
marking head cable and restart
the controller.
If the problem persists, contact
the After-Sales Customer
Service Team.
Error code 9: Open circuit.
The striker unit cable has been
cut or damaged.
Check the condition of the
striker unit cable and restart
the controller.
The striker unit connector has
been damaged or is not
properly connected.
Check the striker unit
connector and restart the
controller.
The marking head cable has
been cut or damaged.
Check the condition of the
marking head cable and restart
the controller.
Contact the After-Sales
Customer Service Team.
Error code 10: Weak current.
The striker unit cable has been
damaged.
Check the condition of the
striker unit cable and restart
the controller.
The striker unit connector has
been damaged or is not
properly connected.
Check the striker unit
connector and restart the
controller.