BLAST CHILLER ISTRUCTION C-2003 06/2011
A
LL 15 Keyboard/membrane alarm
Cause: A pressed push-button has been detected when
panel is switched on.
E
ffect: All keys are disabled.
All relays are disabled. All inputs are disregarded.
The LED indicator of the pressed button flashes.
Beeper: Activated (3 seconds, then a pause of 30 seconds)
u
ntil the mute button is pressed.
Display: Alternates message ALL 15” with standard display
Reset: Switch off the panel then turn it back on (stand-
by).
Note: The appliance cannot be used until this alarm has
been removed.
6
.2.1 Information on alarms:
During alarms, the beeper is activated and the display shows
the message ALL xx.
The alarm message is alternated on the display even when
the beeper has been silenced, until the alarm has been clea-
r
ed.
Alarm relays remain activated as long as the alarm is displa-
yed.
In the case that more than one alarm has been activated,
each one is alternately displayed.
When the beeper is activated, the operator can silence it by
pressing the relative push-button, after which the alarm can
be cleared, by pressing the beeper reset button again.
Power failures will not erase current alarms.
6.2.2
List of other operating faults not indicated:
FAULT CAUSE SOLUTION
Compressor does not operate 1 - Overload switch has cut in 1 - Seek assistance from a service technician
2 - Power failure 2 - Check connection to power lines
Fans do not rotate 1 - Power failure 1 - Check connection to power lines
2 - Fan fault 2 - Seek assistance from a service technician
to replace fan
3 - Condenser fault 3 - Seek assistance from a service technician
to replace condenser
4 - Protective fuse faulty 4 - Seek assistance from a service technician to
replace fuse
Electronic panel does 1 - Power failure 1 - Check connection to power lines
not switch on 2 - Protective fuses broken 2 - Seek assistance from a service technician to
replace fuses
Compressor operates but 1 - Shortage of refrigerant gas 1 - Seek assistance from a service technician
does not cool cell 2 - Solenoid valve fault 2 - Seek assistance from a service technician
3 - Condenser is soiled 3 - Clean the condenser (see par. 4.2)