BLAST CHILLER ISTRUCTION C-200306/2011
2. INSTALLATION
2.1 DATA PLATE INFORMATION
Check that the data specified on the plate correspond to the
characteristics of the power supply (V, kW, Hz, no. phases and
power available).
The dataplate with appliance specifications is located at the
rear exterior of the machine and/or on the electrical boards.
The set-up of individual
units and the installation of
condensers are subject to
the fire-safety regulations of
the country in which the
machine is installed; seek all
necessary advice from the
local fire-fighting authori-
ties.
Bear in mind that the intervention of safety valves or plug
fuses in the refrigerating circuit will lead to the immediate
discharge of refrigerant into the environment.
2.2 REMARKS / MALFUNCTION’S CLAIMS
In case of machine malfunctioning and claim on Blast Chil-
lers delivered in the following way :
Assembled MOD.
w
We ask you to indicate to the dealer / service: machine
model, machine code number and apparatus serial number.
These information are written on the registration label, in-
stalled on the back of machine and inside the door.
Disassembled MOD. t
We ask you to indicate to the dealer / service: machine
model, machine code number and apparatus serial number.
These information are written on the registration label, in-
stalled on top of the control panel.
2.3 POSITIONING
The machine must be installed and commissioned in com-
plete compliance with safety regulations, procedures and
standing laws.
The installation technician bears the responsibility of ensu-
ring compliance with fire safety requirements; seek all ne-
cessary advice from the local fire-fighting authorities.
Position the machine in the allocated site.
Adjust the machine feet until the appliance is perfectly level.
In the case of particularly heavy equipment, use appropriate
lifting means (fig. A - Cap. 1.3).
If the appliance is not perfectly level, correct operation and
condensate flow-off will not be assured.
Avoid
direct exposure to sunlight;
closed sites with high temperatures and poor air circulation;
installing the machine near sources of heat.
2.4 AMBIENT TEMPERATURE AND AIR CIRCULATION
For air-cooled appliances, the maximum ambient tempera-
ture for operation is 32°C. Correct operation cannot be gua-
ranteed at higher temperatures.
The machine may operate safely to a maximum temperature
of 38°C.
Remote condensing units must be installed in special rooms
or outdoors, protected against direct sunlight by a shelter or
roof structure (at the cost of the purchaser).
Sufficient air circulation must be guaranteed at all times.
2.5 ELECTRICAL CONNECTIONS
A dedicated thermal-magnetic circuit breaker compliant
with established regulations must be installed on the ap-
pliance power line.
Connected electrical cables must correspond to the techni-
cal data (as specified on electrical drawings provided by the
installation technician).
Connect the earthing conductor to an efficient earthing sy-
stem.
The manufacturer declines all liability and guarantee obli-
gations in the event of injury to persons or damage to
equipment and objects due to incorrect installation and/or
failure to comply with standing installation regulations.
2.5.1 Connecting the appliance to the power supply
In the event of damage to the power supply cable on the ap-
pliance, have the cable replaced only by a qualied electri-
cian to avoid any risk of personal injury
THESE OPERATIONS MUST BE
PERFORMED BY A CERTIFIED
INSTALLATION TECHNICIAN ONLY
S
erial
~ Hz AW
k
g
WW
W
38Ø-4ØØ/3N 3ØØØ
Machine model AX8 ØØØ 1Ø3 Ø3213
R4Ø4 A 2.2 CLASS T
1
1
IP 21