Basic Quick Start Parameter List
Parameter
Default
Range
Note
00-00
0
0-4
Control Mode:-
0: V/F
1: V/F+PG (Encoder).
2: SLV ( Sensorless Vector)
3: SV ( Vector +Encoder)
4: PMSV
( Permanent Magnet Motor + Encoder)
00-27
0
0-1
HD/ND selection
0: HD (Heavy duty load mode)
1: ND (Normal duty load mode)
00-02
00-00
0-2
Run mode:-
Keypad = 0
Remote = 1
Communication = 2
PLC = 3
00=05
00-00
0-5
Frequency source:-
00-00 = keypad
00-01= Remote control ( Analogue Inputs)
00-02= External up/down frequency control
00-03= Control by Communication
00-04 = Pulse Input
00-05 =PID output
00-01
000
0-1
Run Direction:-
0: Forward
1: Reverse
00-12
50/60Hz
0.1~109%
Max frequency limit. (default 100%)
00-13
0.0
0.0~109%
Min frequency limit. (default 0.0%)
07-09
000
0-1
Stop method:
00-00 = Decel to stop
00-01= Coast to stop
00-02= DC injection braking
00-03= Run signal inhibit ( timer)
during Coast to stop
02-01
**A
**A
Motor overload protection
13-08
000
Factory Reset: Inverter Supply voltage.
2 : 2 wire initialization(230/460V)
3 : 3 wire initialization(230/460V)
4 : 2 wire initialization(200/415V)
5 : 3 wire initialization(200/415V)
6 : 2 wire initialization(200/380V)
7 : 2 wire initialization(200/380V)
Note:- For Full Parameter List see the Instruction manual