31
Group 11: Auxiliary Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
Soft PWM
Function 2
11-69
Gain of
Preventing
Oscillation 3
0.00~200.00 5.00
Note2
11-70
Upper Limit
of
Preventing
Oscillation 3
0.01~100.00 5.00
Note2
11-71
Time
Parameter of
Preventing
Oscillation 3
0~30000 100
Note2
11-72
Switch
Frequency 1
for
Preventing of
Oscillation
Gain
0.01~300.00 30.00
Note2
11-73
Switch
Frequency 2
for
Preventing of
Oscillation
Gain
0.01~300.00 50.00
Note2
*a: KVA means the default value of this
parameter will be changed by different
capacities of inverter.
*b: Default value is 1 only for V/F mode.
Group 12: Monitoring Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
12-00
Display
Screen
Selection
(LED)
00000~77777
From the leftmost
bit, it displays the
screen when
press DSP key in
order.
0: No display
1: Output Current
2: Output Voltage
3: DC Bus
Voltage
4: Heatsink
Temperature
5: PID Feedback
6: AI1 Value
7: AI2 Value
00321
*1
*5
12-01
PID
Feedback
Display
Mode (LED)
0: Display the
Feedback Value
by Integer (xxx)
0 *5
1: Display the
Feedback Value
by the Value
with First
Decimal Place
(xx.x)
2: Display the
Feedback Value
by the Value
with Second
Group 12: Monitoring Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
Decimal Place
(x.xx)
12-02
PID
Feedback
Display Unit
Setting
(LED)
0: xxxxx (no
unit)
0 *5
1: xxxPb
(pressure)
2: xxxFL (flow)
12-03
Line Speed
Display
(LED)
0~60000
1500/
1800
*5
12-04
Line Speed
Display
Mode (LED)
0: Display
Inverter Output
Frequency
0
*1
*5
1: Line Speed
Display at
Integer.(xxxxx)
2: Line Speed
Display at One
Decimal Place.
(xxxx.x)
3: Line Speed
Display at Two
Decimal Places.
(xxx.xx)
4: Line Speed
Display at Three
Decimal Places.
(xx.xxx)
12-05
Status
display of
digital input
terminal
(LED / LCD)
LED display is
shown as
below no input
correspondenc
es to input
andoutput
LCD display is
shown as
below
0000 0000
Input Terminal(S6)
Input Terminal(S5)
Input Terminal(S4)
Input Terminal(S3)
Input Terminal(S2)
Input Terminal(S1)
0:OPEN
1:CLOSE
0
Output Terminal(R3)
Output Terminal(R2)
Output Terminal(R1)
-
12-06
~
12-10
Reserved
12-11
Output
Current of
Current
Fault
Display the
output current
of current fault
-
12-12
Output
Voltage of
Current
Fault
Display the
output voltage
of current fault
-