Group 12: Monitoring Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
12-41
Heatsink
Temperatur
e
Display the
heatsink
temperature of
IGBT
temperature.
-
12-42
RS-485
Error Code
LCD Display:
0000 0000
1: CRC Error
1: Data length Error
1: Data Function Error
1: Parity Error
1: O verrun Error
1: Framing Error
1: Time Out Error
Reserved
LED Display:
(without any
error)
LED Display:
(with certain
error)
1: CRC E rror
1: Data length Error
1: D at a Funct ion Error
1: Parity Error
1: Framing Er ror
1: T im e out Error
Reserv ed
1: Overrun Error
- *7
12-43
Inverter
Status
LCD Display:
0000 0000
1: Inver ter ready
1: Duri ng r unning
1: Duri ng zero speed
1: Dur ing speed agr ee
1: Duri ng faul t det ection
(minor faul t)
1: Duri ng faul t det ection
(major faul t)
Res e r v e d
LED Display:
Inverter ready
1
Running 2
Zero Speed 4
Frequency Agree 8
Warning 16
Error 32
Inverter status
display is the
summed up
value. Ex:
Display of the
value 6 means
the inverter is
running in zero
speed.
101B
12-44 Reserved
12-45
Recent
Fault
Message
Display current
fault message
-
12-46
Previous
Fault
Message
Display
previous fault
message
-
12-47
Previous
Two Fault
Messages
Display
previous two
fault messages
-
12-48
Previous
Three Fault
Messages
Display
previous three
fault messages
-
12-49
Previous
Four Fault
Messages
Display
previous four
fault messages
-
Group 12: Monitoring Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
12-50
DIO Status
of Current
Fault
Display the
DI/DO status of
current fault
Description is
similar to 12-05
-
12-51
Inverter
Status of
Current
Fault
Display the
inverter status
of current fault
Description is
similar to 12-43
-
12-52
Trip Time 1
of Current
Fault
Display the
operation time
of current fault,
12-53 is the
days, while 12-
52 is the
remaining
hours.
-
12-53
Trip Time 2
of Current
Fault
-
12-54
Frequency
Command
of Previous
Fault
Display
frequency
command of
previous fault
-
12-55
Output
Frequency
of Previous
Fault
Display output
frequency of
previous fault
-
12-56
Output
Current of
Previous
Fault
Display output
current of
previous fault
-
12-57
Output
Voltage of
Previous
Fault
Display output
voltage of
previous fault
-
12-58
DC Voltage
of Previous
Fault
Display DC
voltage of
previous fault
-
12-59
DIO Status
of Previous
Fault
Display DI/DO
status of
previous fault
Description is
similar to 12-05
-
12-60
Inverter
Status of
Previous
Fault
Display inverter
status of
previous fault
Description is
similar to 12-43
-
12-61
Trip time 1
of last fault
Display the
operation time
of last time’s
fault, 12-62 is
the days, while
12-61 is the
remaining
hours.
-
12-62
Trip time 2
of last fault
-
12-63
Recent
warning
messages
Display the
recent warning
messages
-
12-64
Previous
warning
message
Display the
previous
warning
-