50
LED display Possible solutions
UT
(flash)
under torque
detection
Check under torque
detection parameters (08-
19 / 08-20).
Check load / application.
bb1
(flash)
External
baseblock
Multi-function input
function set incorrectly.
Check wiring
bb2
(flash)
External
baseblock
bb3
(flash)
External
baseblock
bb4
(flash)
External
baseblock
bb5
(flash)
External
baseblock
bb6
(flash)
External
baseblock
OL1
Motor overload
Check V/f curve.
Check motor rated current
Check and reduce motor
load, check and operation
duty cycle.
Check V/f curve.
Replace inverter with
larger rating.
Check and reduce motor
load, check and operation
dut
c
cle
OL2
Inverter
overload
CE
(flash)
communication
Check connection
Check host computer /
software.
LED display Possible solutions
error
CLB
over current
protection
level B
Check load and duty cycle
operation.
Retry
(flash)
retry
It will disappear after the
period of automatic reset.
EF1
( flash )
External fault
(S1)
Multi-function input
function set incorrectly.
Check wiring
EF2
(flash)
External fault
(S2)
EF3
(flash)
External fault
(S3)
EF4
(flash)
External fault
(S4)
EF5
(flash)
External fault
(S5)
EF6
(flash)
External fault
(S6)
EF9
(flash)
error of
forward/reversal
rotation
Check run command
wiring