EasyManua.ls Logo

TECO JSDE Series - TB Terminal; Wiring for Mechanical Brake

TECO JSDE Series
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
2-1-6 TB Terminal
2-1-7 Wiring for Mechanical Brake
Uninstall BRAKE:
z 50/100/200/300/400/750W series: Use Red wire and yellow wire connecting to DC +24V voltage(No
polarity)
z 550/1KW series: BK outputs from A & F of Motor Power Joint, servo motor can operate normally after
uninstalling.
Yellow Wire
Red Wire
50/100/200/
300/400/750W
550W/1KW
A
F
Name
Terminal
Sign
Detail
R
S
Main circuit power input
terminal
T
Connecting to external AC Power.
Single / 3 Phase 200~230VAC, +10 ~ -15% 50/60Hz ±5%
P
External regeneration
resistance terminal
PC
When using external regeneration, set the resistance power in Cn012.
Please refer to manual to see resistance value
U
Motor terminal wire is red
V
Motor terminal wire is white
Motor-power output
terminal
W
Motor terminal wire is black
Motor-case grounding
terminal
Motor terminal wire is green or yellow-green.