Page #19 background imageLoading...
Page #19 background image
19
2-1-6 TB Terminal
2-1-7 Wiring for Mechanical Brake
Uninstall BRAKE:
z 50/100/200/300/400/750W series: Use Red wire and yellow wire connecting to DC +24V voltage(No
polarity)
z 550/1KW series: BK outputs from A & F of Motor Power Joint, servo motor can operate normally after
uninstalling.
Yellow Wire
Red Wire
50/100/200/
300/400/750W
550W/1KW
A
F
Name
Terminal
Sign
Detail
R
S
Main circuit power input
terminal
T
Connecting to external AC Power.
Single / 3 Phase 200~230VAC, +10 ~ -15% 50/60Hz ±5%
P
External regeneration
resistance terminal
PC
When using external regeneration, set the resistance power in Cn012.
Please refer to manual to see resistance value
U
Motor terminal wire is red
V
Motor terminal wire is white
Motor-power output
terminal
W
Motor terminal wire is black
Motor-case grounding
terminal
Motor terminal wire is green or yellow-green.