ELECTRIC STARTER SERVICE
This section covers the service procedures for 12 volt
electric starters. For diagnosis of the starting circuit see
“Electrical Starter Troubleshooting” in this chapter.
NOTE: Internal service may not be allowed under various
country regulations. Outside the USA consult your local
government authorities regarding servicing regulations.
12 VOLT ELECTRIC STARTERS
1. Remove the plastic dust cover on the bendix end.
(Illust. 5-12)
2. Push down on the spring retainer and remove the
retaining ring. (Illust. 5-13)
5-12
5-13
3. Slide off the spring retainer, anti-drift spring, gear,
and drive nut. (Illust. 5-14)
5-14
4. If internal service is necessary (non-CSA starters
only), scribe a line across the cap assemblies and
armature housing to aid in reassembly.
(Illust. 5-15)
5-15
TOOL PART NO.