Operating Instructions
116
1502C MTDR User Manual
O
F
F
O
F
F
O
F
F
O
N
ac 452.000 ft
Open
Figure 111: 455-ft Cable
5. Change DIST/DIV to 20 ft/div. The entire cable can now be inspected in
detail on the LCD. Turn the
n
o
POSITION control so the cursor travels to
the far right side of the LCD. Keep turning and the cable will be dragged
across the display.
O
F
F
O
F
F
O
F
F
O
N
ac 452.000 ft
Short
Figure 112: 455-ft Cable
A rise or fall is a signature of an impedance mismatch (fault). A dramatic
rise in the pulse indicates and open. A dramatic lowering of the pulse indicates a
short. Variations, such as inductive and capacitive effects on the cable, will
appear as bumps and dips in the waveform. Capacitive faults appear as a
lowering of the pulse (e.g., water in the cable). Inductive faults appear as a rising
of the pulse (e.g., fray). Whenever an abnormality is found, set the cursor at the
beginning of the fault and read the distance to the fault on the distance window
of the LCD.

Table of Contents

Other manuals for Tektronix 1502C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 1502C and is the answer not in the manual?

Tektronix 1502C Specifications

General IconGeneral
BrandTektronix
Model1502C
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals