EasyManuals Logo
Home>Tektronix>Test Equipment>2235

Tektronix 2235 Operator's Manual

Tektronix 2235
53 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
Ge
n
e
r
al
I
n
fo
r
m
ation-2235
ΑΝ
/
US
M
-488
O
p
e
r
ators
Β
TR
IGG
ER
(I
n
te rn
al)
VA
RH
O
L
DO
FF
Control
T
r
igge
r
V
iew
System
Deflectio
n
F
acto
r
I
n
ternal
E
xternal
AC
an
d
DC
Accuracy
Swee
p
R
ate
DC-10
Cali
b
rate
d
R
ange
C
ha
r
acte
r
istics
Delay
Differe
nce B
etween
ΕΧΤ
I
NPU
T
and
E
it
h
er
V
ertical
C
hann
el
Ta
b
le
1-1
(cont)
TR
IGG
ER
SYST
EM
(cont)
Swee
p
L
i
n
ea
r
ity
I
±
5%
.
Same
as ve
r
tical
.
100
m
V
p
er divisio
n
.
1
V
per
division
.
+20%
.
Less
t
han 2
.0
n
s
H
O
R
IZO
N
TA
L
D
EFLE
CTIO
N
SYST
EM
Α
Swee
p
0
.5
s
per
d
ivision to
0
.05
As perd
ivision
in
α
1-2-5
sequence
.
X10
~
magnifier
exten
d
s
maximum
swee
p
s
p
eed
to
5
n
s
p
er
division
.
Β
Swee
p
50
ms
perd
ivision
to
0
.05
As
per
d
ivision
in
α
1-2-5
seq
uence
.
X10
~
mag
n
ifie
r
exte
nds
maximum
swee
p
s
pee
d
to
5
n
s
p
e
r
d
ivisio
n
.
Acc
u
racy
U
nmagnifie
d
M
ag
n
ifie
d
+10°C
to
+35°C
±2%
±3%
0°C
to
+50°C
±3°/
α
±4°/
ο
P
OSITIO
N
Control
R
ange
Start
of
sweep
to
10t
h
division
will
p
osition
p
ast
t
h
e
cente
r
ve
r
tical
graticule
line
i
n
Χ
1
o
r
100t
h
division
in
Χ
10
.
V
ariable
Control
R
ange
Co
n
ti
n
uously
varia
b
le
betwee
n
calib
r
ated
setti
ngs
.
R
educes
t
h
eΑ
~
and
Β
swee
p
s
p
eeds
b
y
at
least
α
factor
of
2
.5
.
Sweep
L
engt
h
I
Greate
r
t
h
an 10
divisio
n
s
.
Α
/
Β
S
WP
S
EP
Ra
nge
I
±3
.5
d ivisions
or
greater
.
Pe
r
formance
R
e
qu
irements
Can
be
set
to
any
p
oi
n
t
of
t
he
trace
t
h
at
can be
d
isplaye
d
.
I
nc
r
eases
Α
Swee
p
h
oldoff
time
by
at
least
α
factor
of
10
.
Delay
Time
Ι
A
pp
lies
to
0
.5
As
p
e
r
divisio
n
and
slower
.
Dial
Control
R
a
n
ge
1
<0
.5
+300
n
s
to
>10
d
ivisio
ns
.
J
itter
O
n
e
p
art
or
less
i
n 20,000
(0
.005%)
of
t
he
maximum
available
~
d
elay
time
.
Differential
Time
M
easurement
Acc
u
racy
+15°C
to
+35°C
±1%
+0
.01
ma
j
or
d
ial
d
ivision
.
0°C
to
+50°C
±2%
+0
.01
ma
j
or
dial
divisio
n
.
REV
NOV
1985

Table of Contents

Other manuals for Tektronix 2235

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2235 and is the answer not in the manual?

Tektronix 2235 Specifications

General IconGeneral
BrandTektronix
Model2235
CategoryTest Equipment
LanguageEnglish

Related product manuals