EasyManuals Logo
Home>Tektronix>Test Equipment>7704A

Tektronix 7704A User Manual

Tektronix 7704A
261 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #115 background imageLoading...
Page #115 background image
1
.
Am
p
lifier
plug-in
unit
(
d
ual
trace)
2
.
Time-b
ase
plug-i
n
unit
Eq
ui
p
ment
R
equire
d
3
.
T
h
ree-inc
h
screwdriver
Control
Settings
32
.
A
d
j
ust
V
ertical
Se
p
aration
α
.
R
emove
Q3416
from
B
oard
(see
F
ig
.
6-37)
.
c
.
Set
t
he
RE
ADO
UT
con
trol
for
visi
b
le
ch
aracters
(all
zeros)
.
d
.
C
HE
CK
-C
RT
d
is
p
lay for
two
rows
of
zeros,
40
zeros
to
α
row
wit
h
no
overla
p
.
T
h
e
two
rows
of
zeros
s
h
ould
b
e
locate
d
vertically
in
t
he middle
of
t
h
e
to
p
and
b
ottom
d
ivi-
sions
of
t h e
graticule
(see
F
ig
.
4-3)
.
RE
ADO
U
T
SYST
EM
ΝΟΤΕ
If
the
R
eadoutSystemwas
deleted
from
the
instrument
being
calibrated
(Option
1),
omit
this
section
of
the
procedure
.
RE
ADO
U
T
G
R
ATI
LLUM
NOTE
The
location
of
adjustments
for
calibration
is
shownon
α pullout,
page
6-35,
in
the
Diagrams
section
.
Set
t
he
7704
Α
controls
as
follows
:
P
O
WER
VER
TICA
L
M
OD
E
VER
TT
R
AC
E
S
EP
A
R
ATIO
N
(
Β
)
ΑT
R
IGG
ERSO
UR
CE
Α
ΙΝΤΕΝ
H
O
R
IZO
N
TA
L
M
OD
E
Β
ΙΝΤΕΝ
Β
T
R
IGG
ER
SO
UR
C
E
I
N
T
EN
SITY
F
OC
U
S
b
.
Set
t
he P
O
WER
switc
h
to
on
.
O
FF
R
IG
HT
Midrange
VER
T
M
OD
E
Midrange
Α
Midrange
VER
T
M
OD
E
Midrange
Set
for
α
welI-clefine
d
d
isplay
O
FF
Midrange
its
soc
k
et
on
Α
34,
R
ea
dout
e
.
AD
JU
ST-
V
ertical
Sep
aration
ad
j
ustment
R
4390
(see
F
ig
.
6-37)
to
position
t
he
two
rows
of
reado
u
t
c
h
aracters
to
t
he midd
le
of
t
he top and
bottom
d
ivisio
n
s
of
t
he
graticule
.
f
.
Set
t h e
P
O
WER
switc
h
to
off
an
d
replace
Q3416
(see
F
ig
.
6-37)
i
n
its
soc
k
et
;
retur
n
t
he P
O
WER
switc
h
to
on
.
ιο
-
Οχ
ι
NO
ΤΕ
T
hese
tolerances
are
provided
as
guides
to
correct
instrument
operation
and
are
not
instrument
specifications
.
ΝΟΤΕ
Calibration-7704A
Service
T
he
V
ertical
Amplifier
Centering
adjustment
must
be
correct
before
making
this
adjustment,
see
step
11
.
F
ig
.
4-3
.
R
ea
dou
t
d
is
p
lay wit
h
Q3416
remove
d
.
4-
23

Table of Contents

Other manuals for Tektronix 7704A