4
.
Solder
t
h
e
bul
b to
t
he
circ
u
it
board
.
If
p
ossible,
use
α
heat
sin
k
to
protect
t
he
bulb
du
ring
sol
d
ering
.
5
.
Install
t
he
switc
h
using
t
h
e
proce
dure d
escri
b
e
d
previou
sly
.
C
.
G
R
ATIC
ULE
BULB
REPL
ACEMEN
T
.
To
replace
t
h
e
graticule
b
ulbs,
first
remove
t
he
plastic
C
R
T
mas
k
,
lig
h
t
filter,
and
metal
lig
h
t s
h
ield
.
Pull
on
the
w
h
ite
tabs to
remove
t
h
e
graticule
lam
p
assem
b
ly
.
Now,
sli
de
t h e
lam
p
retaining
stri
p
s
to
t
he
si
d
e,
off
t
h
e
bulb
b
ase
.
Pull
t
he
bulb
out
of
t
he
circuit
boar
d
.
Reverse
t
he
order
of
removal
for
replacement
.
P
ower
Tra
n
sformer
R
e
p
lacement
.
Replace
t
h
e
power
t r
a
n
sformer
only
wit
h α di
r
ect
re
p
lace
m
en
t
Te
ktronix
tra
n
sformer
.
To
replace
t
h
e
power
transformer,
proceed
as
follows
:
1
.
Remove
Α
31,
Rectifier
an
d
F
ilter
b
oard
,
along
wit
h
t
he
p
ower
transformer
as
give
n
under
Circ
u
it
Boar
d
Re
p
laceme
n
t
.
2
.
U
nsolder
t
he
p
ower-transformer
leads
from
t
h
e
Rectifier
and
F
ilter
boa
r
d
.
Remove
t
h
e
excess
sol
d
er
from
t
he b
oar
d
with
α
vac
uum-ty
p
e
d
esol
d
ering
tool
.
3
.
Remove
t
he b
rass
s
p
ring
retai
n
ers
w
h
ic
h
h
ol
d
t
he
transformer
win
d
ings
and core
in
place
an
d
remove
t
h
ese
items
.
4
.
To
replace
t
h
e
p
ower
tra
n sformer,
reverse
t
he ord
er
of
removal
.
F
use
R
ep
laceme
nt
.
T
he
fuses
use
d
in
t
h
is
instr
u
ment
are
as
follows
:
REV
.
Β
,
NO
V
.
1976
TA
BLE
3-2
F
use
R
ati
n
gs
R
ecalibration
AfterR
ep
air
Maintenance-7704A
Service
After
any
electrical
component
h
as
b
een
replaced,
t
he
calibration
of
t
hat
particular
circuit
s
h
oul
d
b
e c
h
ecked,
as
well as
t
he
cali
b
ration
of
ot
h
er
closely related
circuits
.
Since
t
h
e
low-voltage
su
p
plies
affect
all
circuits,
cali
b
ration
of
t
h
e
e
n
tire
i
n
str
u
ment
s
h
o
u
ld
b
e
ch
eck
e
d
if
wor
k h
as
b
een
done
in
t
he
low-voltage
su
pp
lies
or
if t
he
power
transformer
h
as
bee
n
re
placed
.
See
Section
4
for
α
complete
calibration
proce
d
ure
.
Instrument
R
e
p
ac
k
aging
If
t
he
Tek
tronix
instrument
is
to
b
e
s
h
ipped to
α
Te
ktronix
Service
Center
for
service
or
re
p
air,
attac
h α
tag
s
h
owing
:
owner
(wit
h add
ress)
and
t
he
name
of
an
indivi
du
al
at
yo
u
r
firm
t
h
at
can be
contacte
d
,
complete
instr
u
ment
serial
num
b
er
and α d
escription
of
t
h
e
service
re
qu
ire
d
.
Save
a
n
d
re-
u
se
t
he
p
ackage
in
w
h ic
h
yo
u
r
instrument
was
s
h
ip
p
e
d
.
If t
h
e
original
pac
kaging
is
unfit
for
u
se
or
not
available,
repac
k
age
t
h
e
inst
ru
ment
as
follows
:
1
.
O
b
tain
α carton of
corr
u
gated
cardboa
r
d
h
aving
insi
de
d
imensions
of
no
less
t
han
six inc
h
es
more
t
h
an
t
he
instrument
d
imensions
;
t
h
is
will
allow
for
cu
s
h ioning
.
Refer
to
t
he
following
ta
b
le
for
carton
test
strengt
h
re
q
uirements
.
2
.
S
u
rro
u
nd
t
h
e
instr
u
me
n
t
with
p
olyeth
ylene
s
h
eeting
to
protect
t h e
finis
h of
t
he
instr
u
ment
.
3
.
C
u
s
h
ion
t
h
e
i
n
str
u
ment
on
all
si
des by
tig
h
tly
pac
k
ing
d
unnage
or
u
ret
h
a
ne
foam
between
carton
and
instr
u
-
me
n
t,
allowing
th
ree inc
h
es
on
all
si
d
es
.
4
.
Seal
carton with sh
ipping
tape
or
in
d
ustrial
sta
p
ler
.
S
H
I
PP
I
NGCA
R
TON
TE
STST
RENGT
H
3-
1
9
Circuit
Nu
m
b
er
R
ating
F
unctio
n
L
ocation
F
3001
4
Α
F
ast
L
ine
I
nput
L
ine
Selector
Assem
b
ly
F
3003 2
Α
F
ast
Inverter
L
ine
Selector
Assem
b
ly
Gross
Weig
h
t
(lb)
0-10
Carton
Test
Strengt
h
(l
b
)
200
10-30
275
30-120 375
120-140
500
140-160
600

Table of Contents

Other manuals for Tektronix 7704A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 7704A and is the answer not in the manual?

Tektronix 7704A Specifications

General IconGeneral
BrandTektronix
Model7704A
CategoryTest Equipment
LanguageEnglish

Related product manuals