EasyManuals Logo

Tektronix 7704A User Manual

Tektronix 7704A
261 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #81 background imageLoading...
Page #81 background image
Maintenance-7704A
Service
Control
Settings
.
Set
t
h
e
7704
Α
controls
as
follows
:
P
O
WER
O
FF
VER
TICA
L
MOD
E
R
IG
HT
VERT
T
R
AC
E
S
EP
A
R
ATIO
N
(
Β
)
M
i
d
range
ΑT
RIGG
ERSO
UR
CE
VER
T
M
OD
E
Α
ΙΝΤΕΝ
M
i
d
range
H
O
R
IZO
N
TA
L
MOD
E
Α
Β
ΙΝΤΕΝ
M
i
d
range
Β
T
RIGG
ERSO
UR
C
E
VER
T
M
OD
E
RE
ADO
U
T
O
FF
Ad
j
ust
V
ertical
Interface
Centering
an
d
Gain
.
To
cali-
brate
t
he
V
ertical
Interface,
set
t
h
e
controls
as
given
un
d
er
Control
Settings
a
nd p
roceed
as follows
:
α
.
Disconnect
coaxial
connectors
Ρ
4417
and
Ρ
4418
from
Α
44,
V
ertical
Amplifier
board
(see
F
ig
.
3-3)
.
b
.
Connect
P4417
and
Ρ4418
to
t
h
e
vertical
channels
of
t
he
test
oscilloscope
wit
h
t
he
a
dapters and
cables
.
(If
t
h
e
test
oscilloscope
h
as
α h
ig
h
in
put im p
e
dance, use
50-o
h
m
terminations
at
t
he
vertical-c
hannel
in
p
uts
.)
c
.
Set
t
h
e
P
O
WER
switch to on
.
d
.
Set
t
h
e
test
oscillosco
pe
for
d
ifferential
op
eration
between
t
h
e
vertical
c
hannels
(a
d
de
d d
is
p
lay
mo
d
e
with
one
c
hannel
inverte
d
;
invert
t
h
e
channel to
w
h
ic
h
Ρ4418
is
connecte
d
),
an
d α
sweep
rate
of
100
microsecon
d
s/
d
ivision
.
e
.
Set
t
he
test-oscillosco
pe
vertical
c
h
annels
for
α
deflection
factor
of
50
millivolts/
d
ivision
with
t
h
e in
p
uts
groun
ded
.
f
.
E
stablis
h α
zero-volt
reference
level
for
t
h
e
test-
oscilloscope
d
isplay
by
positioning
t
he
trace
to
t
h
e
center
h
orizontal
line
of
t
he
graticule
.
Do
not ch
ange
t
he
test-oscillosco
pe p
osition
controls
after
setting
t
h
is
level
.
g
.
Set
t h e
vertical
c h
annels
of
t
h
e
test
oscillosco
p
e
for
DC
in
p
ut
cou
p
ling
.
3-
8
h
.
AD
JU
ST-Interface
Centering
a
d
j
ustment
R
2222
(see
F
ig
.
3-4)
for
α
dis
p
lay
DC
level
wit
h
in
0
.2
d
ivision
(10
millivolts)
of
t
he
zero-volt
reference
level
in t
h
e
LEF
T
and
R IG
HT
p
ositions
of
t
h
e
VER
TICA
L
MOD
E switc
h
.
i .
Install
t
h e
signal
stan
d
ar
d
izes
calibration
fixture
in
t
he
R
IG
H
T
VER
T
com
p
artment
.
j .
Set
t
h
e
VER
TICA
L
MOD
E
switc
h
to
R
IG
H
T
.
k
.
Set
t
he
cali
b
ration
fixture
Test switch to
V
ert
or
H
oriz
Gain
an d
t h
e
R
e
p R
ate
switc
h to
10
kH
z
.
Ι
.
AD
JU
ST-Interface
Gain
a
d
j
ustment
R
2247
(see
F ig
.
3-4)
for
α
test-oscillosco
pe d
is
p
lay
of nine
traces wit
h
six
d
ivisions
±0
.9
d
ivision
d
eflection
between
t
h
e
secon
d
an
d
eig
h
t
h
traces
(300
millivolts
with
in
45
millivolts)
.
m
.
Set
t
he P
O
WER
switch to
off
.
η
.
Disconnect
Ρ
4417
an
d Ρ
4418
from
t h e
test
oscil-
loscope
an
d
connect
t
h
em
to
t
h
eir res
p
ective
j
ack
s
on
t
h
e
V
ertical
Am
p
lifier
boar
d
.
t-f-',
0,N
T
OF
ιΝS
Τί
t
ι 1
ΜΕ
%
ηΓ "
F
ig
.
3-3
.
L
ocatio
n
of
Ρ
4417
a
n
d
Ρ
4418
on
A44-
V
ertical
Am
plifie
r
b
oar
d
.

Table of Contents

Other manuals for Tektronix 7704A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 7704A and is the answer not in the manual?

Tektronix 7704A Specifications

General IconGeneral
BrandTektronix
Model7704A
CategoryTest Equipment
LanguageEnglish

Related product manuals