Glossary
amp-second product
The unit of measure dening the maximum amount of pulsed current that can
be measured before the probe core becomes saturated. The amp-second rating
applies only to measurement values between the maximum continuous and
maximum pul
se current ratings of the probe. The amp-second rating is equal
to the peak current multiplied by the pulse width at the 50% point.
auto-balance
A process that removes unwanted DC offsets from the TCPA300 and
TCPA400 circuitry to ensure maximum measurement accur
acy. This process
is performed during the probe degauss routine.
bucking current
Current fed back by the TCPA300 and TCPA400 to the current probe during
DC and low-frequency AC measurements. Bucking c urrent nulls most of the
magnetic eld in the probe core, allowing linear DC and AC measurements
simultaneously.
conventional current ow
The ow of the positive charge in a conductor. Conventional current ow is
from positive to negative. The arrows on current probes point in the direction
of conventional current ow. Conventional current ow is in the opposite
direction of electron current ow.
degauss
A process of eliminating residual magnetism from the probe core by feeding
a decaying sine wave into the core. The degaussing process should be
performed before clamping the probe around a conductor, whenever the probe
becomes saturated by current overloads, or whenever the probe is exposed
to a magnetic eld. The term is derived from one of the units of magnetic
ux density.
electron current ow
The ow of the electrons in a conductor. Electron current ow is from
negative to positive. The arrows on current probes point in the opposite
direction of electron current ow. Electron current ow is in the opposite
direction of conventional current ow.
ux
The density of a magnetic eld. As the n umber of ux lines increases,
the magnetic eld strength increases. Current in the conductor under test
generates ux lines in the probe core by inducing a voltage in the core.
TCPA300/400 Ampliers and TCP300/400 Series Current Probes Service Manual 95