Channels | 2 |
---|---|
Input Coupling | AC, DC, GND |
Vertical Sensitivity | 2 mV/div to 10 V/div |
Interface | USB 2.0 |
Trigger Modes | Edge, Pulse Width |
Operating System Compatibility | Windows XP, Windows Vista |
Safety precautions related to fire and personal injury hazards.
Information on accessing application help and related documents.
Guidance on printing topics from the online help system.
Explanation of terms and symbols used in the online help.
Details on other documents related to the TDSUSB2 application.
List of standard and optional accessories included with the application.
Mandatory software installation and operational restrictions.
Step-by-step guide to deskewing probes and channels on supported instruments.
Description of the application's Windows interface and controls.
Explanation of the items and controls within the application's interface.
How to minimize and maximize the application window.
Default directories and file naming conventions used by the application.
Explanation of file extensions used by the application.
Steps to return to the application from oscilloscope functions.
Procedure for closing the TDSUSB2 application.
Configuring general and advanced application preferences.
Testing high-speed device response to data patterns and signal levels.
Steps to configure selected measurements using the application menus.
Configuring Tier, Direction, Test Point, and Source for Signal Quality tests.
Configuring Port, Device Type, and Source for Droop Tests.
Utility to convert CSV files to TSV files for data analysis.
Steps to start the TDSUSB2 application.
Loading waveform data from .tsv files for tutorial analysis.
Equipment required for downstream signal quality check on Full Speed devices.
Steps to select and configure Full Speed Signal Quality tests.
Configuring measurement options like Tier, Direction, Test Point, and Source.
Equipment required for performing Droop Tests on Low Speed devices.
Steps for setting up equipment for Low Speed Droop Tests.
Steps to select and configure Droop Tests.
Steps to select and configure upstream signal quality tests.
Configuring measurement options for upstream signal quality.
Generating reports for upstream signal quality test results.
Viewing procedural steps for measurements within the application.
Viewing the results obtained from Chirp measurements.
Steps to select and configure upstream signal quality tests for High Speed devices.
Configuring measurement options for High Speed upstream signal quality.
Generating reports for upstream signal quality tests on High Speed devices.
Steps for setting up equipment for Resume measurement.
Steps to select and configure Resume measurements.
Steps for setting up equipment for Suspend measurement.
Steps to select and configure Suspend measurements.
Steps for setting up equipment for Reset from High Speed measurement.
Steps to select and configure Reset from High Speed measurements.
Steps for setting up equipment for Chirp test.
Steps to select and configure Chirp measurements.
Viewing detailed results of Inrush Current measurements.
Viewing detailed results of Signal Quality Check.
Viewing eye diagrams for High Speed measurements.
Reference materials for using R-GPIB commands with the oscilloscope.
Introduction to R-GPIB command syntax for designing automation programs.
USB2.0 limits and user configure limits for Low, Full, and High speed signals.
Definition and calculation of Cross-Over Voltage for Low/Full Speed signals.
Definition and calculation of Cross-Over Voltage for High Speed signals.
Detects signal crossing of eye masks and its results (PASS/FAIL/Conditional PASS).
Tests high-speed device response to data patterns at specific signal levels.
Calculates monotonic violations from signal start to EOP, checks 15-85% levels.
Calculation of falling edge rate in V/us using amplitude and fall time.
Calculates device/HUB resume high-speed operation timing.
Equipment setup for Low Speed Downstream Signal Quality test.
Equipment setup for Low Speed Signal Quality test on HUB Downstream.
Equipment setup for Chirp Test on Device SQ.
Steps for setting up equipment for Inrush test.